Objective To investigate the cytokine expression profiles of blood cells exposed to polyetheretherketone and titanium-6 aluminum-4 vanadium materials in vitro. Materials and methods Coin-shaped samples composed of titanium-6 aluminum-4 vanadium, polyetheretherketone, and blasted polyetheretherketone were manufactured. The surfaces of the coins were characterized using optical interferometry, scanning electron microscopy, and contact angle measurements. Peripheral blood mononuclear cells collected from 10 blood donors were cultured for one, three, and six days in the presence or absence of the coins, and then assayed for cytokine production. Quantification of the peripheral blood mononuclear cells attached to the coins was performed using confocal microscopy after immunofluorescence staining. Results The machined titanium-6 aluminum-4 vanadium coins had a smoother surface topography compared to the machined polyetheretherketone and blasted polyetheretherketone. The highest mean contact angle was noted for the blasted polyetheretherketone, followed by the machined polyetheretherketone and titanium-6 aluminum-4 vanadium. The peripheral blood mononuclear cells produced significantly more proinflammatory cytokines when exposed to the polyetheretherketone surface compared to the titanium-6 aluminum-4 vanadium surface, while the blasted polyetheretherketone induced the highest level of proinflammatory cytokine release from the peripheral blood mononuclear cells. Significantly more cells attached to both polyetheretherketone surfaces, as compared to the titanium-6 aluminum-4 vanadium surface. Conclusion Polyetheretherketone induces a stronger inflammatory response from peripheral blood mononuclear cells than does titanium-6 aluminum-4 vanadium. Surface topography has an impact on cytokine release from peripheral blood mononuclear cells.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0885328218786005 | DOI Listing |
J Prosthet Dent
August 2023
Lecturer, Department of Prosthodontics/Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden; Researcher, Centre for Clinical Research Sörmland, Uppsala University, Eskilstuna, Sweden.
Statement Of Problem: Cobalt chromium (Co-Cr) alloys possess beneficial mechanical properties because alloys, even in thin sections, can resist high mastication forces and exhibit an acceptable bond to the surface porcelain layer. Traditional manufacturing techniques of Co-Cr alloys such as casting have been replaced with newer fabrication techniques, such as milling, laser melting, and presintered milling. Despite scarce documentation, these new manufacturing techniques are being used to fabricate dental and implant constructions.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
December 2021
Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.
Electrosurgical techniques are used during surgery to cauterize, and their damaging effects have primarily been documented in terms of tissue necrosis, charring, and localized heat accumulation. Metallic implants as well as the surgical blade can experience incidental electrosurgical current arcing that results in the generation and transfer of melted metallic particles. This work examines the composition, particle size distribution, and chemical state of the melted alloy surfaces and particles produced in vitro.
View Article and Find Full Text PDFJ Prosthet Dent
January 2022
Assistant Professor, School of Dental Technology, Taipei Medical University, Taipei, Taiwan, Republic of China. Electronic address:
Statement Of Problem: Although studies have reported on selective laser melting (SLM)-fabricated removable partial dentures (RPDs), research addressing the trueness of SLM-fabricated RPD metal frameworks is sparse.
Purpose: The purpose of this in vitro study was to evaluate the trueness of powdered cobalt-chromium (Co-Cr) or titanium-6 aluminum-4 vanadium (Ti-6Al-4V) alloy frameworks for RPDs fabricated by SLM.
Material And Methods: A digital scan of a Kennedy class II mandible typodont was obtained to design an RPD framework by using a computer-aided design (CAD) software program (denoted as CRF).
J Prosthodont
March 2019
Department of Prosthodontics, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN.
Purpose: To evaluate the rebonding strength of ceramics to titanium alloy after disassembling by heat treatment.
Materials And Methods: A total of 40 titanium alloy (titanium-6 aluminum-4 vanadium) disks (4.0 × 6.
J Biomater Appl
August 2018
The Sahlgrenska Academy, Institute of Odontology, Göteborg, Sweden.
Objective To investigate the cytokine expression profiles of blood cells exposed to polyetheretherketone and titanium-6 aluminum-4 vanadium materials in vitro. Materials and methods Coin-shaped samples composed of titanium-6 aluminum-4 vanadium, polyetheretherketone, and blasted polyetheretherketone were manufactured. The surfaces of the coins were characterized using optical interferometry, scanning electron microscopy, and contact angle measurements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!