AI Article Synopsis

  • The Savitzky-Golay filter is commonly used in FTIR analysis for smoothing hydrocarbon mixed gas spectra, but choosing the right parameters like polynomial order and frame size is challenging.
  • Researchers explored methods to optimize these parameters by deriving equations linked to various frequency characteristics, leading to the conclusion that setting the polynomial order to 8 and frame size to 11 provides the best smoothing effect.
  • After applying this optimal configuration to various concentrations of CH4 spectra, the filter significantly reduced the relative errors in absorbance, which is crucial for enhancing the accuracy of qualitative and quantitative analysis of spectral data.

Article Abstract

In the smoothing pretreatment for the quantitative analysis of hydrocarbon mixed gases by Fourier transform infrared analysis (FTIR), the Savitzky- Golay filter is usually used as one of the smoothing preprocessing methods in the Fourier transform infrared spectrum data smoothing pretreatment. However, the parameters of the Savitzky-Golay filter such as the polynomial order and frame size are not easy to decide. There is no one unified choice basis. Users usually adopt multiple sets in the special data set to try, and then select a set of relatively optimal data as the optimizing parameters of the Savitzky-Golay filter. The optimal selection method of the Savitzky-Golay filter parameters was explored, and the concrete calculation equations were deduced according to the relation among the normalized cut-off frequency, the normalized beginning frequency of the stopband, the normalized first side lobe peak frequency of the stopband, the normalized first side lobe peak amplitude with the polynomial order and frame size of the Savitzky-Golay filter parameters. Then when the polynomial order and frame size are set as 8 and 11 respectively according the above conclusion and the characteristics of the actual spectral data, the Savitzky - Golay filter smoothing effect is optimum. Through the acquisition the concentration of 0.1%, 0.2%, 0.5%, 1%, 2%, 5% for the actual CH4 spectra, the relative maximum and minimum error of the raw spectra converted absorbance were 17.230 5% and 0.243 0% respectively, and the relative maximum and minimum error of the smooth spectra converted absorbance were 0.088 0% and 0.088 0% respectively in the second absorption peak. The relative error of converted absorbance was basically stable through the Savitzky-Golay filter after the spectral data preprocessing and it was relatively low, so, it laid a foundation for the late spectral data accurate qualitative and quantitative analysis.

Download full-text PDF

Source

Publication Analysis

Top Keywords

savitzky-golay filter
20
smoothing pretreatment
12
polynomial order
12
order frame
12
frame size
12
spectral data
12
converted absorbance
12
quantitative analysis
8
fourier transform
8
transform infrared
8