A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[A Methane Gas Sensor Based on Mid-Infrared Quantum Cascaded Laser and Multipass Gas Cell]. | LitMetric

According to the principle of mid-infrared absorption spectrum, the fundamental absorption characteristics at the wavelength of 7.5 μm of methane (CH4) molecule was used to design a mid-infrared quantum cascaded laser (QCL) and multi-pass gas cell (MPC)-based methane gas sensor. This sensor uses a thermoelectrically cooled, pulse mode QCL whose central wavelength is 7.5 μm. The QCL wavelength was scanned over CH4 absorption line (1 332.8 cm-1)through adjusting the injection current under the condition of room temperature. Meanwhile, a compact MPC (40 cm long and 800 mL sampling volume) was utilized to achieve an effective optical path length of 16 meters. Additionally, a reference gas cell was occupied and joined a spatial filtering optical structure to meet the requirement of MPC in incidence beam, effectively improved the beam quality, reduced the noise which is caused by the fluctuation of QCL and improved the detection sensitivity of this instrument under the guidance of differential optical absorption spectroscopy method. It indicated that the stability of this instrument is good by means of multiple measurements to the methane gas with different concentration, a detection limit of 1 μmol·mol-1 will be obtained when the signal-to-noise ratio equals 1.

Download full-text PDF

Source

Publication Analysis

Top Keywords

methane gas
12
gas sensor
8
mid-infrared quantum
8
quantum cascaded
8
cascaded laser
8
wavelength μm
8
gas cell
8
gas
5
methane
4
sensor based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!