A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Early-Phase Vascular Healing of Bioabsorbable vs. Durable Polymer-Coated Everolimus-Eluting Stents in Patients With ST-Elevation Myocardial Infarction - 2-Week and 4-Month Analyses With Optical Coherence Tomography. | LitMetric

Background: Despite the revolution of coronary stents, there remain concerns about the risk of stent thrombosis, especially in patients with ST-elevation myocardial infarction (STEMI). The present study compared early vascular healing as a contributing factor to reducing stent thrombosis between Xience everolimus-eluting stents (X-EES) and Synergy everolimus-eluting stents (S-EES) in patients with STEMI.

Methods and results: The present study included 47 patients with STEMI requiring primary percutaneous coronary intervention with X-EES (n=25) or S-EES (n=22). Optical coherence tomography (OCT) assessments of the stented lesions were performed 2 weeks and 4 months after stent implantation. Neointimal strut coverage, malapposition and the frequency of thrombus formation were evaluated. In the 2-week OCT analysis, the proportion of covered struts in S-EES (42.4±15.4%) was significantly higher than in X-EES (26.3±10.1%, P<0.001). In the 4-month OCT analysis, the proportion of covered struts in S-EES (72.2±17.9%) was still significantly higher than in X-EES (62.0±14.9%, P=0.04).

Conclusions: Compared with X-EES, S-EES showed a higher proportion of covered struts in the early phase after stent implantation for STEMI patients.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.CJ-18-0230DOI Listing

Publication Analysis

Top Keywords

everolimus-eluting stents
12
vascular healing
8
patients st-elevation
8
st-elevation myocardial
8
optical coherence
8
coherence tomography
8
stent thrombosis
8
early-phase vascular
4
healing bioabsorbable
4
bioabsorbable durable
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!