A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An unusual foreign body aspiration requiring an unusual retrieval technique. | LitMetric

An unusual foreign body aspiration requiring an unusual retrieval technique.

J Thorac Dis

Department of Medicine, Interventional Pulmonology Section, New York Medical College, Westchester Medical Center, Valhalla, NY, USA.

Published: May 2018

Foreign body aspiration during medical procedures has been reported in the literature. These iatrogenic incidents could be related to instruments malfunction or to accidental occurrences during medical treatment. In this paper, we present a report of a woman coming for a laparoscopic abdominal hysterectomy who developed intraoperative bronchospasm. In an attempt to administer aerosolized albuterol, the resident anesthesia provider fractured the Luer-lock tip of the 60-cc syringe, which he was using to hold the albuterol nebulizer. The plastic tip was dislodged into the endotracheal tube (ETT). On further inspection with a fiberoptic instrument the plastic tip was located loosely adherent to the distal part of the ETT and was held in place by the moisture, which had precipitated in the distal tube. An intraoperative consult with interventional pulmonary medicine was obtained after unsuccessfully attempting to retrieve the foreign body with a grasper. The syringe tip was then removed using a Fogarty balloon catheter that was threaded through the hole of the plastic tip.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6006123PMC
http://dx.doi.org/10.21037/jtd.2018.03.118DOI Listing

Publication Analysis

Top Keywords

foreign body
12
body aspiration
8
unusual foreign
4
aspiration requiring
4
requiring unusual
4
unusual retrieval
4
retrieval technique
4
technique foreign
4
aspiration medical
4
medical procedures
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!