A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessing the Safety and Efficacy of the ClearRing™ Implant for the Treatment of Benign Prostatic Hyperplasia in a Canine Model. | LitMetric

Background: Transurethral resection of the prostate is the most common procedure for the treatment of benign prostatic hyperplasia (BPH). Although effective, transurethral resection of the prostate can be associated with side effects including prolonged recovery, storage and voiding symptoms, risk of acute urinary retention.

Objectives: In this study, we describe a new minimally invasive device for the treatment of lower urinary track symptoms due to BPH, implanting a nitinol C shape ring in a circular incision in the prostatic tissue, surrounding the urethra, done by electrocuting blade over a dilatation balloon.

Methods: Two groups of dogs (4/ group) were implanted with the device under anesthesia. Clinical observation, body weight and weekly blood and urinary tests were performed throughout the study period to evaluate safety. Fluoroscopy and cystoscopy were used throughout the study period to evaluate implant condition and urethral dilatation. At the end of 3 weeks (Group I) or 3 months (Group II), the animals were sacrificed. The implantation site was examined macroscopically and histologically to evaluate urethral dilatation and tissue response.

Results: The presence of the ClearRing™ implant in an animal's prostate was associated with significant dilatation of the prostatic urethra. Fever, pain, behavior disturbances or gross hematuria, when occurred, resolved within 72 hours post procedure and no severe adverse events were observed. There was no evidence of prostatic hyperplasia associated to ring implantation. Partial epithelial coverage of the implant surface was observed without evidence of encrustation.

Conclusion: The ClearRing™ implant seems a feasible minimally invasive procedure for relieving lower urinary track symptoms due to BPH.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6036580PMC
http://dx.doi.org/10.1159/000447220DOI Listing

Publication Analysis

Top Keywords

clearring™ implant
12
prostatic hyperplasia
12
treatment benign
8
benign prostatic
8
transurethral resection
8
resection prostate
8
prostate associated
8
minimally invasive
8
lower urinary
8
urinary track
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!