Background Recombinant human insulin-like growth factor 1 (rhIGF-I) has been approved as an orphan drug for the treatment of growth failure in children and adolescents with severe primary IGF-I deficiency (SPIGFD) with little pharmacokinetic data available. Therefore, sequential measurements of serum IGF-I, glucose, potassium, insulin and cortisol were performed in patients treated with rhIGF-I to evaluate their significance in safety and efficacy. Methods Repetitive blood samples were taken after meals before and 30, 60, 120, 180 and 360 min after rhIGF-I injections in two male patients with Laron syndrome at times of dose adjustments. Results Maximal IGF-I concentrations were observed 2 h after injections (495 ng/mL) and concentrations were still higher 6 h after injections than at baseline (303 ng/mL vs. 137 ng/mL). Thirteen percent of all and 33% of maximum IGF-I concentrations were greater than +2 standard deviation score (SDS) calculated for bone age (BA) (IGF-I SDS BA) rather than chronological age (CA) as BA was significantly delayed to CA by 3.2 years (p=0.0007). Height velocities correlated with individual maximum IGF-I SDS BA (ρ=0.735; p<0.0001). Serum insulin, cortisol and glucose did not correlate with IGF-I concentrations, but serum potassium showed a negative correlation (ρ=-0.364; p<0.0001) with IGF-I concentrations. Conclusions Sequential measurements of serum IGF-I, glucose and potassium in patients with Laron syndrome may aid in optimizing and individualizing rhIGF-I treatment. IGF-I concentrations should be referenced according to BA which better reflects the biological age. The inverse correlation of IGF-I and serum potassium concentrations after injections of rhIGF-I has not been reported before and warrants further consideration.

Download full-text PDF

Source
http://dx.doi.org/10.1515/jpem-2018-0139DOI Listing

Publication Analysis

Top Keywords

sequential measurements
8
igf-i
8
laron syndrome
8
recombinant human
8
igf-i concentrations
8
maximum igf-i
8
igf-i sds
8
measurements igf-i
4
igf-i serum
4
concentrations
4

Similar Publications

Laser reduction of graphene oxide (GO) is a promising approach for achieving flexible, robust, and electrically conductive graphene/polymer composites. Resulting composite materials show significant technological potential for energy storage, sensing, and bioelectronics. However, in the case of insulating polymers, the properties of electrodes show severely limited performance.

View Article and Find Full Text PDF

The effective knowledge of emissivity is pivotal to obtain reliable temperature measurements through non-contact techniques like pyrometry and thermal imaging. This is fundamental in high-temperature applications since material emissivity strongly depends on temperature conditions. Given the recent attention in high-temperature applications, especially for replacing fossil-fuel-dependent heating with greener solutions in energy-intensive processes, renewed interest in characterizing materials radiant properties rose.

View Article and Find Full Text PDF

Parkinson's disease (PD) is characterized by a slow, short-stepping, shuffling gait pattern caused by a combination of motor control limitations due to a reduction in dopaminergic neurons. Gait disorders are indicators of global health, cognitive status, and risk of falls and increase with disease progression. Therefore, the use of quantitative information on the gait mechanisms of PD patients is a promising approach, particularly for monitoring gait disorders and potentially informing therapeutic interventions, though it is not yet a well-established tool for early diagnosis or direct assessment of disease progression.

View Article and Find Full Text PDF

Water pipelines in water diversion projects can leak, leading to soil deformation and ground subsidence, necessitating research into soil deformation monitoring technology. This study conducted model tests to monitor soil deformation around leaking buried water pipelines using distributed fiber optic strain sensing (DFOSS) technology based on optical frequency domain reflectometry (OFDR). By arranging strain measurement fibers in a pipe-soil model, we investigated how leak location, leak size, pipe burial depth, and water flow velocity affect soil strain field monitoring results.

View Article and Find Full Text PDF

In this paper, a novel particle filter based on one-step smoothing is proposed for nonlinear systems with random one-step delay and missing measurements. Such problems are commonly encountered in networked control systems, where random one-step delay and missing measurements significantly increase the difficulty of dynamic state estimation. The particle filter is a nonlinear filtering method based on sequential Monte Carlo sampling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!