Being able to measure 3-D flow velocity and volumetric flow rate effectively in the cardiovascular system is valuable but remains a significant challenge in both clinical practice and research. Currently, there has not been an effective and practical solution to the measurement of volume flow using ultrasound imaging systems due to challenges in existing 3-D imaging techniques and high system cost. In this study, a new technique for quantifying volumetric flow rate from the cross-sectional imaging plane of the blood vessel was developed by using speckle decorrelation (SDC), 2-D high-frame-rate imaging with a standard 1-D array transducer, microbubble contrast agents, and ultrasound imaging velocimetry (UIV). Through SDC analysis of microbubble signals acquired with a very high frame rate and by using UIV to estimate the two in-plane flow velocity components, the third and out-of-plane velocity component can be obtained over time and integrated to estimate volume flow. The proposed technique was evaluated on a wall-less flow phantom in both steady and pulsatile flow. UIV in the longitudinal direction was conducted as a reference. The influences of frame rate, mechanical index (MI), orientation of imaging plane, and compounding on velocity estimation were also studied. In addition, an in vivo trial on the abdominal aorta of a rabbit was conducted. The results show that the new system can estimate volume flow with an averaged error of 3.65% ± 2.37% at a flow rate of 360 mL/min and a peak velocity of 0.45 m/s, and an error of 5.03% ± 2.73% at a flow rate of 723 mL/min and a peak velocity of 0.8 m/s. The accuracy of the flow velocity and volumetric flow rate estimation directly depend on the imaging frame rate. With a frame rate of 6000 Hz, a velocity up to 0.8 m/s can be correctly estimated. A higher mechanical index (MI = 0.42) is shown to produce greater errors (up to 21.78±0.49%, compared to 3.65±2.37% at MI = 0.19). An in vivo trial, where velocities up to 1 m/s were correctly measured, demonstrated the potential of the technique in clinical applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TUFFC.2018.2850535 | DOI Listing |
Ultrasound J
January 2025
Health Sciences North Research Institute, Sudbury, ON, Canada.
The duration of mechanical systole-also termed the flow time (FT) or left ventricular ejection time (LVET)-is measured by Doppler ultrasound and increasingly used as a stroke volume (SV) surrogate to guide patient care. Nevertheless, confusion exists as to the determinants of FT and a critical evaluation of this measure is needed. Using Doppler ultrasound of the left ventricular outflow tract velocity time integral (LVOT VTI) as well as strain and strain rate echocardiography as grounding principles, this brief commentary offers a model for the independent influences of FT.
View Article and Find Full Text PDFAppl Microbiol Biotechnol
January 2025
Department of Chemistry, Biochemistry and Pharmaceutical Sciences, University of Bern, Freiestrasse 3, 3012, Bern, Switzerland.
A new strategy has been developed to successfully produce the active component danshensu ex vivo. For this purpose, phenylalanine dehydrogenase from Bacillus sphaericus was combined with the novel hydroxyphenylpyruvate reductase from Mentha x piperita, thereby providing an in situ cofactor regeneration throughout the conversion process. The purified enzymes were co-immobilized and subsequently employed in batch biotransformation, resulting in 60% conversion of 10 mM L-dopa within 24 h, with a catalytic amount of NAD as cofactor.
View Article and Find Full Text PDFExp Physiol
January 2025
Centre for Healthy Ageing, Health Futures Institute, Murdoch University, Perth, Australia.
Blood flow restriction (BFR) combined with low work rate exercise can enhance muscular and cardiovascular fitness. However, whether neural mechanisms mediate these enhancements remains unknown. This study examined changes in corticospinal excitability and motor cortical inhibition following arm cycle ergometry with and without BFR.
View Article and Find Full Text PDFJ Chromatogr Sci
January 2025
Faculty of Pharmacy, Department of Analytical Chemistry, Istanbul Health and Technology University, Istanbul 34469, Turkey.
This study presents a combination of High Performance Liquid Chromatography (HPLC) and ultraviolet (UV) detection that provides the quantification of agnuside in human plasma specimens. Reverse-phase chromatographic separation was carried out with C18 column (150 mm × 4.6 mm × 5 μm), at 25°C with isocratic elution of the mobile phase containing methanol: 0.
View Article and Find Full Text PDFFront Pharmacol
January 2025
The Third Clinical Medical School, Guangzhou University of Chinese Medicine, Guangzhou, China.
Background: The Beclin-1/Bcl-2 complex plays a pivotal role in regulating both autophagy and apoptosis in osteoblasts affected by osteoporosis. This study first investigates whether the Bushen Jianpi Huoxue Formula can enhance the cellular function of osteoblasts. Additionally, it initially explores the functional mechanism of Beclin-1/Bcl-2-related apoptosis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!