Combinational drug delivery successfully merges the benefits of nanotechnology and combination therapy by providing diversity to improve the carrier properties and better control over tailoring them as per the need of cancer treatment. A combination of conventional chemotherapeutic agent; docetaxel (DTX) and antioxidant agent; alpha lipoic acid (ALA) which acts by preventing metastasis may fulfill idealness of control and targeted drug delivery against breast cancer. The objective of the current study is to develop a reverse-phase HPLC-UV method for simultaneous determination of DTX and ALA in lipid-based nanoformulations. DTX and ALA were separated on Intersil® ODS (C18) column (250 × 4.6 mm, 5 μm) with a mobile phase consisting of acetonitrile: sodium acetate buffer (pH 3.5; 10 mM) (65:35% v/v) run in isocratic mode at a flow rate of 1 mL/min. The developed method was validated as per ICH guidelines. The method showed linearity in the concentration range of 1-15 μg/mL for DTX and 2-30 μg/mL for ALA. It can detect minimum 200 ng/mL of DTX and 500 ng/mL of ALA. The method was further successfully applied in lipid-based formulation characterization. In conclusion, a simple, accurate and precise reverse-phase HPLC-UV method was established for simultaneous determination of DTX and ALA in nanoformulations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/chromsci/bmy064 | DOI Listing |
JAMA Netw Open
January 2025
Division of Endocrinology and Metabolism, Department of Medicine, University of Calgary, Calgary, Alberta, Canada.
Importance: Using albumin-adjusted calcium is commonly recommended for for measuring calcium, but with little empirical evidence to support the practice.
Objective: To assess the correlation between total calcium measurements (with or without adjustment) vs the ionized calcium level as a reference standard.
Design, Setting, And Participants: This was a population-based cross-sectional study in the province of Alberta, Canada, including adults tested for serum total calcium and ionized calcium simultaneously between January 1, 2013, and October 31, 2019.
Mikrochim Acta
January 2025
Department of General Surgery, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, 266035, China.
A lateral flow assay (LFA) was developed for the simultaneous or separate detection of mercury ion and silver ion based on isothermal nucleic acid amplification. T-Hg-T and C-Ag-C were utilized in the isothermal nucleic acid amplification strategy to form specific complementary base pairs. Under the action of KF polymerase and endonuclease Nt.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
The State Key Laboratory of Complex Electromagnetic Environment Effects on Electronic and Information System, Luoyang 471004, China.
A multi-band high-sensitivity microwave sensor is reported. The two resonance units are based on complementary square spiral resonators (CSSRs) and produce four measurement bands through parasitic resonances. The four frequency bands are 2.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
January 2025
Department of Cardiovascular Medicine, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan.
Aims: Left ventricular (LV) diastolic dysfunction and heart failure with preserved ejection fraction (HFpEF) are common cardiac complications of patients with systemic sclerosis (SSc). Exercise stress echocardiography is often used in symptomatic patients with SSc to detect abnormal increases in pulmonary pressures during exercise, but the pathophysiologic and prognostic significance of exercise stress echocardiography to assess the presence of HFpEF in these patients is unclear.
Methods And Results: Patients with SSc (n=140) underwent ergometry exercise stress echocardiography with simultaneous expired gas analysis.
Anal Chem
January 2025
Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-41061, United States.
Glow discharge optical emission spectrometry (GDOES) allows fast and simultaneous multielemental analysis directly from solids and depth profiling down to the nanometer scale, which is critical for thin-film (TF) characterization. Nevertheless, operating conditions for the best limits of detection (LODs) are compromised in lieu of the best sputtering crater shapes for depth resolution. In addition, the fast transient signals from ultra-TFs do not permit the optimal sampling statistics of bulk analysis such that LODs are further compromised.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!