A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Field based pilot-scale drinking water distribution system: Simulation of long hydraulic retention times and microbiological mediated monochloramine decay. | LitMetric

Drinking water distribution systems with long hydraulic retention times (HRTs) commonly encounter rapid microbiological-mediated monochloramine decay that results in microbial regrowth and nitrification with reduction in alkalinity. In this paper, we report the design and operation of a field-based pilot-scale distribution system (PDS) operated at flows that simulate long HRTs (∼10 days) to promote rapid microbiological monochloramine decay over long periods. The PDS is designed to enable the testing of chemical treatment for the control of nitrification and monochloramine decay. The PDS has two identical cylindrical polyethylene tanks (DS & DS), each of 1 m diameter and 1.8 m height (∼1 kL) holding 900 m of polyethylene (PE) tubing with sampling points every 300 m intervals. Microbial mediated decay (determined by the Fm test) of monochloramine occurred as treated (alum coagulated and flocculated) and chloraminated water passed through the DSs. In this manuscript we report: •An inexpensive, flexible and compact system that can be readily set-up at a full-scale water treatment plant, requiring minimal supervision for operation.•A 'draw & fill' system for achieving control on HRT's through the pipes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6036862PMC
http://dx.doi.org/10.1016/j.mex.2018.06.015DOI Listing

Publication Analysis

Top Keywords

monochloramine decay
16
drinking water
8
water distribution
8
distribution system
8
long hydraulic
8
hydraulic retention
8
retention times
8
monochloramine
5
decay
5
field based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!