Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We report a novel portable 17 kg system based on a quadrupole mass spectrometer (QMS) with an electronic power consumption of 24 W. The system can be used for the in-field identification of gases and volatile/semivolatile organic compounds (VOCs/SVOCs). The mass analyser is a custom-made quadrupole mass filter with a Brubaker pre-filter that gives a mass range of m/z 1-500. It is an upgrade of the previous m/z 1-200 range triple filter analyser system. Analyser design was optimized using 3D numerical simulations as a performance trade-off between single and triple filter designs while maintaining high sensitivity and ease of integration. This also required enhanced design of the electronic control unit (ECU) compared to the previous triple filter ECU designs with lower power consumption, size, weight and cost of the overall system. Another major ECU improvement includes high stability of DC voltage control and ultra-low RF drift, which is important for in-field applications that require stable mass peaks for reliable quantitative analysis and continuous monitoring. Experimental results are presented for the perfluorotributylamine (PFTBA) calibrant and acetone to assess the functionality of the instrument. Performance comparison between the dual and triple filter quadrupole analysers has also been done. Mass spectra are given for methyl benzoate (cocaine simulant), piperidine (phencyclidine simulant), cyclohexanone (C4 simulant) and 2-nitrotoluene (TNT simulant) to assess potential capability for the identification of threat compounds. All spectral results show good correlation with the NIST library mass spectra with unit resolution obtained for spectral peaks within a m/z 1-400 mass range.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c8an00862k | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!