A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Interobserver and intraobserver reliability of different methods of examination for presence of palmaris longus and examination of fifth superficial flexor function. | LitMetric

The palmaris longus is harvested as a tendon graft in various surgical procedures. Several tests are used to assess the presence of palmaris longus tendon. In the present study, we attempted to assess the interobserver and intraobserver reliability of five of the most famous methods and also the examination of fifth superficial flexor function. Two observers, who had been trained on the tests and had practiced them, examined 105 volunteers on two separate occasions and in 1-month interval the results were recorded. The reliability of each method was assessed with Kappa measurement. Kappa ranged from 0.541 (moderate reliability) to 0.813 (almost complete agreement) for palmaris. The highest interobserver and intraobserver reliability and also the best agreement with other tests were of Schaeffer. The lowest kappa was for Thompson and the others have good to excellent reliability. Kappa for interobserver and intraobserver reliability for the fifth flexor were 0.415 and 0.500 (moderate reliability), respectively. The tests that were assessed have good reliability except for Thompson that has a moderate one. It seems that the standard test (Schaeffer) is the best method for the assessment of the absence or presence of palmaris longus. The method used for the evaluation of fifth superficial flexor variations assessment has a moderate interobserver and intraobserver reliability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6026822PMC
http://dx.doi.org/10.5115/acb.2018.51.2.79DOI Listing

Publication Analysis

Top Keywords

interobserver intraobserver
20
intraobserver reliability
20
palmaris longus
16
presence palmaris
12
superficial flexor
12
reliability
10
methods examination
8
examination superficial
8
flexor function
8
moderate reliability
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!