A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantification of radioactivity by planar gamma-camera images, a promoted method of absorbed dose in the thyroid after iodine-131 treatment. | LitMetric

Iodine-131 (I) is an essential and widely used radioisotope in thyroid diseases and animal experiments. Planar imaging has been considered the most popular method for I thyroid uptake radioactive activity quantification. The ROI defining section is essential and can affect the accuracy of quantitative results. However, a consistent method has not been proposed. In this study, a UC-ROI defining method based on ULWL setting and colour display grade was applied. Three steps were performed: image acquisition of five standard activity models and obtaining the exact value that the counts per radioactive activity contributes to the ROI; image acquisition of 20 rat thyroids and obtaining the counts of the ROI (thyroid); and calculating the rat thyroid radioactive activity and comparing these values with the true values. The accuracy of quantification activity of I in rat thyroid reached 2.62% ± 0.41%. The mean quantification within 5% could be achieved in 19 of 20 rat thyroids. No significant difference existed between calculated thyroid I activity and true values with a paired matched-test (t = -0.384, P = 0.706 > 0.05). The results indicated that with the UC-ROI defining method, more accurate thyroid uptake I radioactive activity quantification by SPECT planar imaging can be achieved in vivo rat study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6033874PMC
http://dx.doi.org/10.1038/s41598-018-28571-yDOI Listing

Publication Analysis

Top Keywords

radioactive activity
16
thyroid
8
planar imaging
8
thyroid uptake
8
uptake radioactive
8
activity quantification
8
uc-roi defining
8
defining method
8
image acquisition
8
rat thyroids
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!