AI Article Synopsis

  • Many studies have focused on using eutectic gallium-indium as a conductive ink for creating stretchable sensors, but traditional mold-based methods suffer from inconsistent results due to manual fabrication.
  • This study utilized direct ink writing to enhance the stability and reproducibility of sensor manufacturing by optimizing process variables like syringe material.
  • The new technique not only improved the accuracy of creating microchannels but also allowed for the development of a seamless glove-type sensor, streamlining the fabrication process.

Article Abstract

Given the need for stretchable sensors, many studies have been conducted on eutectic gallium-indium, which has superior properties as a conductive ink. However, it has remained a challenge to manufacture sensors in a consistent and reproducible manner because conventional mold-based fabrication still depends highly on manual techniques. To overcome this limitation, the direct ink writing was used in this study, focusing on improving the stability of writing by exploring issues related to failure and ensuring the consistency of the microchannel by selecting appropriate process variables, including the syringe material. As a result, multiple sensors produced under the same manufacturing conditions had similar behaviors. This fabrication technique improved the accuracy of manufacturing a microchannel, and its behavior was predicted successfully by a simple mathematical model, which was confirmed by nondestructive inspections of the microchannel. In developing a one-piece glove-type sensor without an assembly process, the efficiency of the fabrication technique was also emphasized.

Download full-text PDF

Source
http://dx.doi.org/10.1089/soro.2017.0103DOI Listing

Publication Analysis

Top Keywords

consistent reproducible
8
direct ink
8
ink writing
8
eutectic gallium-indium
8
fabrication technique
8
reproducible direct
4
writing eutectic
4
gallium-indium high-quality
4
high-quality soft
4
sensors
4

Similar Publications

Ultrasound localization microscopy (ULM) enables microvascular imaging at spatial resolutions beyond the acoustic diffraction limit, offering significant clinical potentials. However, ULM performance relies heavily on microbubble (MB) signal sparsity, the number of detected MBs, and signal-to-noise ratio (SNR), all of which vary in clinical scenarios involving bolus MB injections. These sources of variations underscore the need to optimize MB dosage, data acquisition timing, and imaging settings in order to standardize and optimize ULM of microvasculature.

View Article and Find Full Text PDF

The increasing interest in DNA methylation (DNAm) analysis within the forensic scientific community prompted a collaborative project by Ge.F.I.

View Article and Find Full Text PDF

Background: The Multidimensional Psychological Flexibility Inventory (MPFI) is a measure of all facets of psychological flexibility and inflexibility, potentially important processes of change in psychological treatment for chronic pain. In some contexts, it can be considered too long. The aim of this study was, therefore, to validate a short form MPFI (MPFI-24P) in a chronic pain sample.

View Article and Find Full Text PDF

Background: High-risk pregnancy leads to uncertainty and stress in pregnant women due to the threatened of mother and fetus health. The Uncertainty Stress Scale High-Risk Pregnancy Version, a 54-item Chinese version (USS-HRPV-C), has been widely used to assess the uncertainty and stress that women experience during pregnancy. However, the length of the scale may result in a burden for respondents.

View Article and Find Full Text PDF

Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study.

JMIR Form Res

January 2025

Department of Biomedical Informatics, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.

Background: The iAide2 (Tokai) physical activity monitoring system includes diverse measurements and wireless features useful to researchers. The iAide2's sleep measurement capabilities have not been compared to validated sleep measurement standards in any published work.

Objective: We aimed to assess the iAide2's sleep duration and total sleep time (TST) measurement performance and perform calibration if needed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!