Increasing the requirements on telecommunications systems such as the need for higher data rates and connectivity via the Internet of things results in continuously increasing amounts of electromagnetic radiation in ever-higher telecommunications bands (up to terahertz). This can generate unwanted electromagnetic radiation that can affect the operation of electronic devices and human health. Here, we demonstrate that nonconductive and lightweight, graphene-based composites can shield more than 99.99% of the electromagnetic energy in the sub-THz range mainly via absorption. This contrasts with state-of-the-art electromagnetic radiation shielding materials that simply redirect the energy of the radiation from a protected area via conduction-based reflection mechanisms. This shifts the problem of electromagnetic pollution from one place to another. We have demonstrated that the proposed composites can be fabricated by industrial compatible methods and are characterized by specific shielding efficiency values that exceed 30 dB cm3 g-1, which is more than those for typical metals used today. Therefore these materials might help to solve the problem of electromagnetic environmental pollution.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c8nr02793eDOI Listing

Publication Analysis

Top Keywords

electromagnetic radiation
12
radiation shielding
8
problem electromagnetic
8
electromagnetic
6
radiation
5
graphene-based plastic
4
plastic absorber
4
absorber total
4
total sub-terahertz
4
sub-terahertz radiation
4

Similar Publications

Construction of reusable fluorescent assembled 3D-printed hydrogen-based models to simulate minimally invasive resection of complex liver cancer.

PLoS One

December 2024

Department of General Surgery, Cancer center, Division of Hepatobiliary and Pancreatic Surgery, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang Province, China.

Complex liver cancer is often difficult to expose or dissect, and the surgery is often challenging. 3D-printed models may realistically present 3D anatomical structure, which has certain value in planning and training of liver surgery. However, the existing 3D-printed models are all monolithic models, which are difficult to reuse and limited in clinical application.

View Article and Find Full Text PDF

Optimizing dual energy X-ray image enhancement using a novel hybrid fusion method.

J Xray Sci Technol

December 2024

School of Electrical and Information Engineering, Tianjin University, Nankai District, Tianjin, China.

Background: Airport security is still a main concern for assuring passenger safety and stopping illegal activity. Dual-energy X-ray Imaging (DEXI) is one of the most important technologies for detecting hidden items in passenger luggage. However, noise in DEXI images, arising from various sources such as electronic interference and fluctuations in X-ray intensity, can compromise the effectiveness of object identification.

View Article and Find Full Text PDF

Carbon-based light addressable potential aptasensor based on the synergy of C-MXene@rGO and OPD@NGQDs for low-density lipoprotein detection.

Mikrochim Acta

December 2024

School of Life and Environmental Sciences, School of Intellectual Property, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People's Republic of China.

A novel carbon-based light-addressable potentiometric aptasensor (C-LAPS) was constructed for detection low-density lipoprotein (LDL) in serum. Carboxylated TiC MXene @reduced graphene oxide (C-MXene@rGO) was used as interface and o-phenylenediamine functionalized nitrogen-doped graphene quantum dots (OPD@NGQDs) as the photoelectric conversion element. The photosensitive layers composed of OPD@NGQDs/C-MXene@rGO exhibit superior photoelectric conversion efficiency and excellent biocompatibility, which contribute to an improved response signal.

View Article and Find Full Text PDF

Photon-counting detector computed tomography (PCD-CT) offers energy-resolved CT data with enhanced resolution, reduced electronic noise, and improved tissue contrast. This study aimed to evaluate the visibility of intracranial perforating arteries on ultra-high-resolution (UHR) CT angiography (CTA) on PCD-CT. A retrospective analysis of intracranial UHR PCD-CTA was performed for 30 patients.

View Article and Find Full Text PDF

Marine microalgae are emerging as promising sources of polyphenols, renowned for their health-promoting benefits. Recovering polyphenols from microalgae requires suitable treatment and extraction techniques to ensure their release from the biomass and analytical methodologies to assess their efficiency. This review provides a comprehensive comparison of traditional and cutting-edge extraction and analytical procedures applied for polyphenolic characterization in marine microalgae over the past 26 years, with a unique perspective on optimizing their recovery and identification.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!