Distributed x-ray radiation dosimetry is crucial in diverse security areas with significant environmental and human impacts such as nuclear waste management, radiotherapy, or radioprotection devices. We present a fast, real-time dosimetry detection system based on flexible oxide thin-film transistors that show a quantitative shift in threshold voltage of up to 3.4 V/gray upon exposure to ionizing radiation. The transistors use indium-gallium-zinc-oxide as a semiconductor and a multilayer dielectric based on silicon oxide and tantalum oxide. Our measurements demonstrate that the threshold voltage shift is caused by the accumulation of positive ionization charge in the dielectric layer due to high-energy photon absorption in the high- dielectric. The high mobility combined with a steep subthreshold slope of the transistor allows for fast, reliable, and ultralow-power readout of the deposited radiation dose. The order-of-magnitude variation in transistor channel impedance upon exposure to radiation makes it possible to use a low-cost, passive radiofrequency identification sensor tag for its readout. In this way, we demonstrate a passive, programmable, wireless sensor that reports in real time the excess of critical radiation doses.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6025907 | PMC |
http://dx.doi.org/10.1126/sciadv.aat1825 | DOI Listing |
Cureus
December 2024
Physical Medicine and Rehabilitation, Centro de Reabilitação do Norte, Vila Nova de Gaia, PRT.
Background: Painful hemiplegic shoulder (PHS) is a prevalent and challenging complication following a stroke and can significantly impair a patient's engagement in rehabilitation, leading to poorer functional outcomes and extended hospital stays. This retrospective cohort study aims to investigate the incidence, etiology, and management of PHS in stroke inpatients, focusing on the effectiveness of various therapeutic interventions.
Methods: We conducted a retrospective analysis of subacute stroke inpatients who developed PHS during rehabilitation at a single center.
Nat Commun
December 2024
Department of Electrical and Computer Engineering, Princeton University, Princeton, NJ, USA.
Millimeter-wave and terahertz integrated circuits and chips are expected to serve as the backbone for future wireless networks and high resolution sensing. However, design of these integrated circuits and chips can be quite complex, requiring years of human expertise, careful tailoring of hand crafted circuit topologies and co-design with parameterized and pre-selected templates of electromagnetic structures. These structures (radiative and non-radiative, single-port and multi-ports) are subsequently optimized through ad-hoc methods and parameter sweeps.
View Article and Find Full Text PDFResearch (Wash D C)
December 2024
Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA.
Metamaterials hold great potential to enhance the imaging performance of magnetic resonance imaging (MRI) as auxiliary devices, due to their unique ability to confine and enhance electromagnetic fields. Despite their promise, the current implementation of metamaterials faces obstacles for practical clinical adoption due to several notable limitations, including their bulky and rigid structures, deviations from optimal resonance frequency, and inevitable interference with the radiofrequency (RF) transmission field in MRI. Herein, we address these restrictions by introducing a flexible and smart metamaterial that enhances sensitivity by conforming to patient anatomies while ensuring comfort during MRI procedures.
View Article and Find Full Text PDFSci Rep
September 2024
James Watt School of Engineering, University of Glasgow, Glasgow, G12 8QQ, UK.
Current approaches to activity-assisted living (AAL) are complex, expensive, and intrusive, which reduces their practicality and end user acceptance. However, emerging technologies such as artificial intelligence and wireless communications offer new opportunities to enhance AAL systems. These improvements could potentially lower healthcare costs and reduce hospitalisations by enabling more effective identification, monitoring, and localisation of hazardous activities, ensuring rapid response to emergencies.
View Article and Find Full Text PDFLab Chip
September 2024
Quantum and Nanotechnologies Research Centre, National Research Council Canada, Edmonton, AB T6G 2M9, Canada.
This paper demonstrates the integration of complementary split-ring resonators (CSSRs) with digital microfluidics (DMF) sample manipulation for passive, on-chip radio-frequency (RF) sensing. Integration is accomplished by having the DMF and the RF-sensing components share the same ground plane: by designing the RF-resonant openings directly into the ground plane of a DMF device, both droplet motion and sensing are achieved, adding a new on-board detection mode for use in DMF. The system was modelled to determine basic features and to balance various factors that need to be optimized to maintain both functionalities (DMF-enabled droplet movement and RF detection) on the same chip.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!