Front Oncol
Department of Molecular Imaging, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.
Published: June 2018
Background: Convolutional neural networks (CNNs) have been shown to be powerful tools to assist with object detection and-like a human observer-may be trained based on a relatively small cohort of reference subjects. Rapid, accurate organ recognition in medical imaging permits a variety of new quantitative diagnostic techniques. In the case of therapy with targeted radionuclides, it may permit comprehensive radiation dose analysis in a manner that would often be prohibitively time-consuming using conventional methods.
Methods: An automated image segmentation tool was developed based on three-dimensional CNNs to detect right and left kidney contours on non-contrast CT images. Model was trained based on 89 manually contoured cases and tested on a cohort of patients receiving therapy with Lu-prostate-specific membrane antigen-617 for metastatic prostate cancer. Automatically generated contours were compared with those drawn by an expert and assessed for similarity based on dice score, mean distance-to-agreement, and total segmented volume. Further, the contours were applied to voxel dose maps computed from post-treatment quantitative SPECT imaging to estimate renal radiation dose from therapy.
Results: Neural network segmentation was able to identify right and left kidneys in all patients with a high degree of accuracy. The system was integrated into the hospital image database, returning contours for a selected study in approximately 90 s. Mean dice score was 0.91 and 0.86 for right and left kidneys, respectively. Poor performance was observed in three patients with cystic kidneys of which only few were included in the training data. No significant difference in mean radiation absorbed dose was observed between the manual and automated algorithms.
Conclusion: Automated contouring using CNNs shows promise in providing quantitative assessment of functional SPECT and possibly PET images; in this case demonstrating comparable accuracy for radiation dose interpretation in unsealed source therapy relative to a human observer.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6010550 | PMC |
http://dx.doi.org/10.3389/fonc.2018.00215 | DOI Listing |
Radiol Cardiothorac Imaging
April 2025
Division of Diagnostic Imaging, The Chaim Sheba Medical Center, Tel Hashomer, 2 Derech Sheba St, Ramat Gan 5265601, Israel.
Purpose To evaluate the accuracy of chest ultra-low-dose CT (ULDCT) as compared with normal-dose CT in the evaluation of pneumonia in individuals who are immunocompromised. Materials and Methods This prospective study included 54 adults who were immunocompromised (median age, 62 years [IQR, 47.75-69.
View Article and Find Full Text PDFJ Appl Clin Med Phys
March 2025
Department of Comprehensive Radiation Oncology, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan.
Purpose: This study aims to quantify and compare the dosimetric effects of varying thicknesses of StrataXRT, a silicone-based gel, and other topical agents on the skin surface during volumetric modulated arc therapy (VMAT) for breast cancer.
Methods: A VMAT plan was created for breast cancer treatment using a female RANDO phantom with a prescription dose of 50 Gy in 25 fractions. The planning target volume (PTV) encompassed the left breast and the regional lymph nodes.
Nanotheranostics
March 2025
Research Center for Radioisotope, Radiopharmaceuticals and Biodosimetry Technology, National Research and Innovation Agency, Serpong, Indonesia.
This study aimed to synthesize cetuximab (CTX) conjugated hydroxyapatite zirconium (HApZr-CTX) as a nanocarrier for active delivery of photosensitizer and therapeutic radionuclide. The system enabled targeted radioenhancer in X-ray dynamic therapy and radioimmunotherapy for lung cancer. The results showed that HApZr-CTX had the main characteristics of hydroxyapatite crystal in X-ray powder diffraction (XRD), with particle size twice bigger, according to DLS-PSA and TEM measurements.
View Article and Find Full Text PDFFront Oncol
February 2025
Department of Radiation Oncology, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.
Purpose: Radioresistance remains a predominant factor contributing to local recurrence in esophageal squamous cell carcinoma (ESCC). SATB2, as a transcriptional co-gene, may affect the radioresistance of cancer cells. Consequently, this study aims to elucidate the mechanism by which SATB2 modulates radiotherapy resistance in esophageal cancer.
View Article and Find Full Text PDFFront Oncol
February 2025
Biophysics Department, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany.
Tumor motion is a major challenge for scanned ion-beam therapy. In the case of lung tumors, strong under- and overdosage can be induced due to the high density gradients between the tumor- and bone tissues compared to lung tissues. This work proposes a non-invasive concept for 4D monitoring of high density gradients in carbon ion beam therapy, by detecting charged fragments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!