Background: Some surgeons change gloves and instruments after the extirpative phase of cancer surgery with the intent of reducing the risk of local and wound recurrence. Although this practice is conceptually appealing, the evidence that gloves or instruments act as vectors of cancer-cell seeding in the clinical setting is weak. To determine the potential effect of further investigation of this question, we surveyed the practices and beliefs of a broad spectrum of surgeons who operate on cancer patients.

Methods: Using a modified Dillman approach, a survey was mailed to all 945 general surgeons listed in the College of Physicians and Surgeons of Ontario public registry. The survey consisted of multiple-choice and free-text response questions. Responses were tabulated and grouped into themes, including specific intraoperative events and surgeon training. Predictive variables were analyzed by chi-square test.

Results: Of 459 surveys returned (adjusted response rate: 46%), 351 met the inclusion criteria for retention. Of those respondents, 52% reported that they change gloves during cancer resections with the intent of decreasing the risk of tumour seeding, and 40%, that they change instruments for that purpose. The proportion of respondents indicating that they take measures to protect the wound was 73% for laparoscopic cancer resections and 31% for open resections. Training and years in practice predicted some of the foregoing behaviours. The most commonly cited basis for adopting specific strategies to prevent tumour seeding was "gut feeling," followed by clinical training. Most respondents believe that it is possible or probable that surgical gloves or instruments harbour malignant cells, but that a cancer recurrence proceeding from that situation is unlikely.

Conclusions: There is no consensus on how gloves and instruments should be handled in cancer operations. Further investigation is warranted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6023557PMC
http://dx.doi.org/10.3747/co.25.3924DOI Listing

Publication Analysis

Top Keywords

gloves instruments
16
tumour seeding
12
prevent tumour
8
cancer surgery
8
change gloves
8
cancer resections
8
cancer
7
gloves
5
instruments
5
glove instrument
4

Similar Publications

Wearable motion capture gloves enable the precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design, including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design.

View Article and Find Full Text PDF

Objective: to analyze the association between participation in training activities and the adherence to and use of personal protective equipment by workers and professionals involved in Health Residency Programs in Primary Health Care during the COVID-19 pandemic.

Methods: a cross-sectional study in Brazil between August/2020 and March/2021. We utilized the EPI-APS COVID-19 instrument and its adapted version for resident professionals.

View Article and Find Full Text PDF

Enhancing safety with an AI-empowered assessment and monitoring system for BSL-3 facilities.

Heliyon

January 2025

Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, 35, Keyan Road, Zhunan Town, Miaoli County, 350, Taiwan.

Introduction: The COVID-19 pandemic has created an urgent demand for research, which has spurred the development of enhanced biosafety protocols in biosafety level (BSL)-3 laboratories to safeguard against the risks associated with handling highly contagious pathogens. Laboratory management failures can pose significant hazards.

Methods: An external system captured images of personnel entering a laboratory, which were then analyzed by an AI-based system to verify their compliance with personal protective equipment (PPE) regulations, thereby introducing an additional layer of protection.

View Article and Find Full Text PDF

Fiber-based strain sensors, as wearable integrated devices, have shown substantial promise in health monitoring. However, current sensors suffer from limited tunability in sensing performance, constraining their adaptability to diverse human motions. Drawing inspiration from the structure of the spiranthes sinensis, this study introduces a unique textile wrapping technique to coil flexible silver (Ag) yarn around the surface of multifilament elastic polyurethane (PU), thereby constructing a helical structure fiber-based strain sensor.

View Article and Find Full Text PDF

Human hands have over 20 degrees of freedom, enabled by a complex system of bones, muscles, and joints. Hand differences can significantly impair dexterity and independence in daily activities. Accurate assessment of hand function, particularly digit movement, is vital for effective intervention and rehabilitation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!