Synthetic cathinones are a type of drug belonging to group of new psychoactive substances (NPSs). The illicit market for these substances is characterized by the continuous introduction to the market of new analogs to evade legislation and to avoid detection. New screening and confirmation assays are therefore needed, mainly in forensic/clinical samples. In the current development, a porous membrane-protected, micro-solid-phase extraction (μ-SPE) has been developed for the assessment of several cathinones in urine. The μ-SPE device consisted of a cone-shaped polypropylene (PP) porous membrane containing the adsorbent (molecularly imprinted polymers, MIPs, synthesized for the first time for this class of drugs). MIPs were prepared using ethylone and 3-methylmethcathinone (3-MMC) as templates, ethylene glycol dimethacrylate (EGDMA) as a functional monomer, divinylbenzene (DVB) as a cross-linker, and 2,2´-azobisisobutyronitrile (AIBN) as an initiator. The prepared ethylone-based MIP and 3-MMC-based MIP have been fully characterized and evaluated as new selective adsorbents for μ-SPE. Cathinones separation/determination was performed by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Optimum loading conditions (pH 5.0, loading for 4.0 minutes under orbital-horizontal shaking at 200 rpm) and elution conditions [2.0 mL of 75:20:5 heptane/2-propanol/ammonium hydroxide and ultrasounds assistance (37 kHz, 325 W) for 4.0 minutes] were found for ethylone-based MIP. Validation (intra-day and inter-day precision and analytical recovery) showed RSD values lower than 9 and 10% for intra-day and inter-day precision, and within the 88%-101% range for intra-day and inter-day analytical recovery.

Download full-text PDF

Source
http://dx.doi.org/10.1002/dta.2448DOI Listing

Publication Analysis

Top Keywords

intra-day inter-day
12
molecularly imprinted
8
micro-solid-phase extraction
8
synthetic cathinones
8
ethylone-based mip
8
inter-day precision
8
analytical recovery
8
hplc-ms/ms combined
4
combined membrane-protected
4
membrane-protected molecularly
4

Similar Publications

The Schirmer strip measures tear volume in millimeters. A major limitation of the Schirmer strip is that it does not measure tear volume in a volumetric unit. Furthermore, the linearity range, lower limit of detection (LLOD), and lower limit of quantification (LLOQ) are not established.

View Article and Find Full Text PDF

A new thin film was fabricated using FeO@SiO-polyoxometalate (POM) as the coating and it was coupled with a HPLC-UV to develop a method for the selective determination of ibuprofen, paracetamol and diclofenac (as the model analytes) from human plasma and urine samples. The prepared magnetic POM was coated on the pores and surface of cotton yarn to prepare the extracting device. The prepared sorbent was characterized by several techniques including: FT-IR, XRD, BET, SEM, and VSM analysis.

View Article and Find Full Text PDF

Bile acids (BAs), not only promote the absorption of fat-soluble nutrients and regulate the metabolism of multiple substances but also have a potential role as diagnostic and prognostic indicators in a variety of diseases such as cholestasis, hepatocellular carcinoma, and diabetes mellitus. Here, a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of 50 BAs was developed and validated. Sample preparation included internal standard spiking, followed by protein precipitation, centrifugation, solvent evaporation, and reconstitution.

View Article and Find Full Text PDF

The medicinal fungus Phellinus Igniarius (P. igniarius) has been demonstrated to possess a variety of pharmacological effects, including anti-oxidant, anti-tumor, blood circulation promotion, anti-diarrheal and sedative properties, etc. In order to gain a deeper understanding of the components in P.

View Article and Find Full Text PDF

In this study, an automatic magnetic solid phase extraction method was developed to determine six parent neonicotinoids (NEOs) and three of their metabolites in breast milk, serum and urine samples. As key extraction parameters, the sorbent amount, washing solvent and elution solvent were optimized to 4 mg of HLB packing magnetic sorbent, pure water and acetonitrile, respectively. Recoveries of the analytes ranged between 81% and 121% for bovine milk samples, 64% and 122% for fetal bovine serum samples and 81% and 109% for pooled urine samples, with RSDs of <20%.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?