Objectives: The role of aortic angulation in attenuating procedural success in balloon-expandable (BE) and self-expandable (SE) transcatheter aortic valve replacement (TAVR) has been controversial.

Methods: We retrospectively assessed patients undergoing SE and BE TAVR who had an aortic angle measured on multidetector computed tomography at a single tertiary referral center. The primary outcome was device success, measured per the Valve Academic Research Consortium-2 criteria. Clinical outcomes at 30 days (including mortality) were also assessed.

Results: A total of 251 patients were identified; 182 patients received a BE valve and 69 patients an SE valve. The median aortic angle was 46.8° (range 24.4-70°) in the BE group and 43.3° (range 20-71°) in the SE group. In multivariate logistic regression analysis, aortic angulation did not affect device success. Mortality at 30 days and 12 months and postprocedural clinical outcomes were similarly not associated with aortic angulation.

Conclusion: In this cohort of patients undergoing BE and SE TAVR over a wide range of aortic angles, we found no associations between angle and device success or any other clinical metrics. Increased aortic angulation does not adversely affect outcomes in BE or SE TAVR.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000488933DOI Listing

Publication Analysis

Top Keywords

aortic angulation
16
device success
12
aortic
10
transcatheter aortic
8
aortic valve
8
valve replacement
8
patients undergoing
8
undergoing tavr
8
aortic angle
8
clinical outcomes
8

Similar Publications

Objective: To identify the risk factors associated with moderate to severe perivalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) and to construct a prediction model for this risk.

Methods: A retrospective analysis was conducted on 128 patients with severe aortic stenosis who had received TAVR in The Second Hospital of Hebei Medical University from January 2019 to January 2024. The length of the aortic regurgitation bundle and annular circumference ratio were measured by transesophageal echocardiography immediately after the valve implantation.

View Article and Find Full Text PDF

Background: Repair of the regurgitant bicuspid aortic valve is an attractive alternative to valve replacement. Although good long-term outcomes have been reported, postoperative aortic stenosis remains a major late cause of repair failure in bicuspid aortic valves. Sinus plication is effective for creating a more symmetrical commissural angle, leading to a decrease in the mean transvalvular pressure gradient.

View Article and Find Full Text PDF

Introduction/aim: The partial deployment technique (PDT) is an unconventional option of T-branch deployment to allow target arteries (TAs) cannulation/stenting from the upper arm access, in case of narrow (NPA: <25mm) or severely angulated (APA: >60°) aorta. Aim of this study was to report outcomes of the endovascular repair of complex aortic (c-AAAs) and thoracoabdominal (TAAAs) aneurysms by T-branch and PDT.

Methods: All consecutive patients underwent urgent endovascular repair of c-AAAs and TAAAs by T-branch (Cook-Medical, Bloomington, IN, US) and PDT from 2021 to 2023 were analyzed.

View Article and Find Full Text PDF

In situ Laser Fenestrations of Visceral Endografts (InLoVE) Midterm Outcomes From a Multicentre Study.

Eur J Vasc Endovasc Surg

December 2024

Division of Vascular Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Department of Clinical Science and Education, Karolinska Institutet, Södersjukhuset, Stockholm, Sweden.

Objective: Emergent complex abdominal aortic diseases are challenging to treat. During in situ laser fenestration (ISLF), aortic branches are covered and flow is restored with in situ fenestration of the stent graft, with promising midterm results. This study aimed to expand on the limited body of knowledge of midterm outcomes of ISLF in renovisceral aortic pathology in a multicentre setting.

View Article and Find Full Text PDF
Article Synopsis
  • The study examined the risk factors for developing type I endoleak in patients undergoing elective endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA).
  • A total of 105 patients were analyzed, dividing them into those who experienced endoleak (23) and those who did not (82), comparing demographic and clinical characteristics between the two groups.
  • High hostile neck index (HNI) was identified as a significant independent predictor of type I endoleak, with a specific cut-off value determined for predicting endoleak risk.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!