AI Article Synopsis

  • The study examines how the uneven distribution of radiopharmaceuticals affects tumor control probability (TCP) in a model of micrometastases, which are small cancerous growths.
  • Researchers utilized specific cancer cell lines grown as spheroids to analyze how well these treatments penetrate and damage cancer cells.
  • Results indicated that specific cancer cells (MDA-MB-468) showed a TCP greater than 0.5 when treated with a radiopeptide, suggesting potential effectiveness in curing micrometastases in that particular cell type.

Article Abstract

The spatial distribution of radiopharmaceuticals that emit short-range high linear-energy-transfer electrons greatly affects the absorbed dose and their biological effectiveness. The purpose of this study was to investigate the effect of heterogeneous radionuclide distribution on tumor control probability (TCP) in a micrometastases model. Cancer cell lines; MDA-MB-468, SQ20B and 231-H2N were grown as spheroids to represent micrometastases. The intracellular distribution of a representative radiopeptide (In-labelled epidermal growth factor, EGF) and radioimmunotherapeutic (In-labelled Trastuzumab) was determined in cell internalization experiments. The intratumoral distribution was evaluated by microautoradiography of spheroids. γH2AX staining was performed on spheroid sections to correlate DNA damage with radionuclide distribution. Experimental surviving fractions ( ) were obtained using clonogenic assays. A random closed-packed algorithm, which models the random packing behavior of cells and reflects variation in the radii of cells and nuclei, was used to simulate 3-D spheroids. Calculated survival fractions ( ) were generated using an iterative modelling method based on Monte Carlo determined absorbed dose with the PENELOPE code and were compared to ( ). Radiobiological parameters deduced from experimental results and MC simulations were used to predict the TCP for a 3-D spheroid model. Calculated SFs were in good agreement with experimental data, particularly when an increased value for relative biological effectiveness (RBE) was applied to self-dose deposited by sources located in the nucleus and when radiobiological parameters were adjusted to account for dose protraction. Only in MDA-MB-468 spheroids treated with In-EGF was a TCP>0.5 achieved, indicating that for this cell type the radiopeptide would be curative when targeting micrometastases. This is attributed to the relative radiosensitivity of MDA-MB-468 cells, high nuclear uptake of the radiopeptide and uniform distribution of radioactivity throughout the spheroid. It is imperative to include biological endpoints when evaluating the distribution of radionuclides in models emulating micrometastatic disease. The spatial distribution of radioactivity is a clear determinant of biological effect and TCP as demonstrated in this study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6330061PMC
http://dx.doi.org/10.2967/jnumed.117.207308DOI Listing

Publication Analysis

Top Keywords

radionuclide distribution
12
distribution
9
targeting micrometastases
8
heterogeneous radionuclide
8
distribution tumor
8
tumor control
8
control probability
8
spatial distribution
8
absorbed dose
8
biological effectiveness
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!