A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pulmonary Emphysema Quantification on Ultra-Low-Dose Computed Tomography Using Model-Based Iterative Reconstruction With or Without Lung Setting. | LitMetric

Objectives: To evaluate the influence of model-based iterative reconstruction (MBIR) with lung setting and conventional setting on pulmonary emphysema quantification by ultra-low-dose computed tomography (ULDCT) compared with standard-dose CT (SDCT).

Methods: Forty-five patients who underwent ULDCT (0.18 ± 0.02 mSv) and SDCT (6.66 ± 2.69 mSv) were analyzed in this retrospective study. Images were reconstructed using filtered back projection (FBP) with smooth and sharp kernels and MBIR with conventional and lung settings. Extent of emphysema was evaluated using fully automated software. Correlation between ULDCT and SDCT was assessed by interclass correlation coefficiency (ICC) and Bland-Altman analysis.

Results: Excellent correlation was seen between MBIR with conventional setting on ULDCT and FBP with smooth kernel on SDCT (ICC, 0.97; bias, -0.31%) and between MBIR with lung setting on ULDCT and FBP with sharp kernel on SDCT (ICC, 0.82; bias, -2.10%).

Conclusion: Model-based iterative reconstruction improved the agreement between ULDCT and SDCT on emphysema quantification.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RCT.0000000000000755DOI Listing

Publication Analysis

Top Keywords

emphysema quantification
12
model-based iterative
12
iterative reconstruction
12
lung setting
12
pulmonary emphysema
8
quantification ultra-low-dose
8
ultra-low-dose computed
8
computed tomography
8
mbir lung
8
conventional setting
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!