Duration of Catheter Use in Patients with Diabetes Using Continuous Subcutaneous Insulin Infusion: A Review.

Diabetes Technol Ther

1 Research Platform on obesity, metabolism and diabetes, Institut de Recherches Cliniques de Montréal (IRCM) , Montréal, Québec, Canada .

Published: July 2018

Increasing proportions of patients with diabetes use continuous subcutaneous insulin infusion (CSII) therapy mostly due to its clinical efficacy and flexibility for insulin dosing and adjustments. Some challenges are nevertheless associated with this technology. A key and underlooked component of CSII technical difficulties is the subcutaneous catheter used to infuse insulin. Several adverse events (AEs) have been experienced by patients in relation to catheters, such as blockage, kinking, and insertion site reactions, including irritation, infections, lipohypertrophies etc., all of which could compromise the metabolic control. With the objective of minimizing these AEs, recommendations for changing catheters every 2-3 days have historically been provided by manufacturers based on reports derived from small studies and anecdotal data. The aim of this review was to provide an updated analysis of current recommendations and patients' practices in relation to frequency of catheter change. Our main findings are: (1) adequately designed and powered studies investigating optimal catheter wearing time are still lacking; (2) increasing catheter wearing time is generally associated with increased frequency of catheter AEs; (3) however, interpatient variability is large, with some individuals needing to change their catheters every 2-3 days, whereas others probably being able to keep them in place for longer periods without problems. Further research is thus warranted to provide more solid and evidence-based recommendations while exploring personalized approaches at the same time. Increasing catheter wear life without significant side effects is an important goal to simplify CSII therapy and reduce its associated costs and burdens.

Download full-text PDF

Source
http://dx.doi.org/10.1089/dia.2018.0110DOI Listing

Publication Analysis

Top Keywords

patients diabetes
8
diabetes continuous
8
continuous subcutaneous
8
subcutaneous insulin
8
insulin infusion
8
csii therapy
8
catheters 2-3
8
2-3 days
8
frequency catheter
8
catheter wearing
8

Similar Publications

Lipoprotein(a) Atherosclerotic Cardiovascular Disease Risk Score Development and Prediction in Primary Prevention From Real-World Data.

Circ Genom Precis Med

January 2025

Mary and Steve Wen Cardiovascular Division, Department of Medicine, University of California, Los Angeles. (W.F., N.D.W.).

Background: Lp(a; Lipoprotein[a]) is a predictor of atherosclerotic cardiovascular disease (ASCVD); however, there are few algorithms incorporating Lp(a), especially from real-world settings. We developed an electronic health record (EHR)-based risk prediction algorithm including Lp(a).

Methods: Utilizing a large EHR database, we categorized Lp(a) cut points at 25, 50, and 75 mg/dL and constructed 10-year ASCVD risk prediction models incorporating Lp(a), with external validation in a pooled cohort of 4 US prospective studies.

View Article and Find Full Text PDF

Distal tibial fractures are common lower-limb injuries and are generally associated with a high risk of postoperative complications, especially in patients with multiple medical comorbidities. This study sought to ascertain the efficacy of retrograde intramedullary tibial nails (RTN) for treating extra-articular distal tibial fractures in high-risk patients. Between January 2019 and December 2021, 13 patients considered at high risk for postoperative complications underwent RTN fixation.

View Article and Find Full Text PDF

Novel approach to managing two enormous bezoars with successive snare-tip electrocautery: A case report.

World J Gastrointest Endosc

January 2025

Division of Gastroenterology and Hepatology, Department of Internal Medicine, Lukang Christian Hospital, Changhua 505002, Taiwan.

Background: Gastric bezoars are indigestible masses that can lead to gastrointestinal obstruction and ulceration. Standard treatments include endoscopic mechanical lithotripsy with a polypectomy snare and Coca-Cola dissolution therapy or a combination of both approaches. However, giant bezoars frequently require multiple treatment sessions and extended hospital stays.

View Article and Find Full Text PDF

Background: Aortic stenosis (AS) is treated through transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR), with diabetes being prevalent among these patients. Inflammation participates in the pathogenesis of AS, and emerging evidence suggests that TAVI may exert anti-inflammatory effects. Given the established link between diabetes and inflammation, we sought to evaluate the impact of aortic valve replacement (AVR) on glycemic control.

View Article and Find Full Text PDF

Objective: To investigate the altered characteristics of cortical morphology and individual-based morphological brain networks in type 2 diabetes mellitus (T2DM), as well as the neural network mechanisms underlying cognitive impairment in T2DM.

Methods: A total of 150 T2DM patients and 130 healthy controls (HCs) were recruited in this study. The study used voxel- and surface-based morphometric analyses to investigate morphological alterations (including gray matter volume, cortical thickness, cortical surface area, and localized gyrus index) in the brains of T2DM patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!