A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical Relevance of Bone Density Values from CT Related to Dental Implant Stability: A Retrospective Study. | LitMetric

Clinical Relevance of Bone Density Values from CT Related to Dental Implant Stability: A Retrospective Study.

Biomed Res Int

Department of Biomedical and Neuromotor Sciences, Unit of Periodontology and Implantology, University of Bologna, Via San Vitale 59, 40125 Bologna, Italy.

Published: January 2019

Purpose: The majority of the techniques used to assess the primary implant stability are subjective and empirical and can be used during or after the surgery. The aim of this study is to evaluate the bone density prior to surgery, in order to give recommendations to the clinician about the best surgical technique and the type of implant which is needed.

Materials And Methods: A surgeon operated on 75 patients for 269 implants over the period 2010-2014. He required a CT to plan the surgery and he documented the type, the diameters, and the lengths of the implants, the insertion torque, and the ISQ values. At a later stage another clinician measured bone density and cortical thickness. We endeavoured to get the most accurate superimposition between the implants placed by the surgeon and those placed by the clinician.

Results: In maxilla ISQ showed a significant positive correlation with HU values detected for coronal-buccal ( = 0.302; = 0.020) and middle-lingual ( = 0.295; = 0.023). Torque showed a positive correlation with cortical bone thickness at the middle of the ridge ( = 0.196; = 0.032).

Conclusion: It is important to take into consideration the Hounsfield Units and the cortical thickness as predictive parameters during the preoperative assessment, with regard to the choice of the implant type as well as the surgical technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6000841PMC
http://dx.doi.org/10.1155/2018/6758245DOI Listing

Publication Analysis

Top Keywords

bone density
12
implant stability
8
surgical technique
8
cortical thickness
8
positive correlation
8
clinical relevance
4
bone
4
relevance bone
4
density values
4
values dental
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!