Background: I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy and I-FP-CIT dopamine transporter single photon emission computed tomography (DAT-SPECT) provide specific information that distinguish Parkinson's disease (PD) from parkinsonian syndromes other than PD (non-PD), including atypical parkinsonian disorder (APD) and non-PD other than APD (nPD-nAPD). The purpose of this study was to determine whether combining DAT-SPECT and MIBG myocardial scintigraphy using multiparametric scoring system (MSS) could improve diagnostic test accuracy in discriminating PD from APD or discriminating PD from nPD-nAPD.

Methods: A total of 52 patients, including 36 PD, eight APD and eight nPD-nAPD, underwent both MIBG myocardial scintigraphy and DAT-SPECT, were evaluated. The heart-to-mediastinum (H/M) ratios (early and delayed), washout-rate (WR), the average (Ave) and asymmetry index (AI) of specific binding ratio (SBR) were calculated. Cutoff values were determined, using ROC analysis, for discriminating PD from APD and for discriminating PD from nPD-nAPD, on five parameters. All cases were scored as either 1 (PD) or 0 (nPD-nAPD or APD) for each parameter according to its threshold in each discrimination. These individual scores were summed for each case, yielding a combined score to obtain a cutoff value for the MSS in each discrimination.

Results: For discriminating PD from nPD-nAPD, the highest accuracy was 80% at a cutoff value of 19% for the WR and a cut off value of 2 improved diagnostic accuracy to 84% for MSS. For discriminating PD from APD, the highest accuracy was 86% at a cutoff value of 2.8 for the H/M ratio (late) and a cut off value of 2 showed diagnostic accuracy of 86% for MSS.

Conclusion: A MSS has comparable or better accuracy compared to each parameter of MIBG myocardial scintigraphy and DAT-SPECT in distinguishing PD from nPD-nAPD or distinguishing PD from APD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6015794PMC
http://dx.doi.org/10.33160/yam.2018.06.004DOI Listing

Publication Analysis

Top Keywords

myocardial scintigraphy
20
mibg myocardial
16
discriminating apd
12
parkinson's disease
8
disease parkinsonian
8
parkinsonian syndromes
8
apd
8
apd npd-napd
8
apd discriminating
8
scintigraphy dat-spect
8

Similar Publications

On the Effect of the Patient Table on Attenuation in Myocardial Perfusion Imaging SPECT.

EJNMMI Phys

January 2025

Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia, University Hospital (Ruhr University Bochum), Medical Faculty OWL (Bielefeld University), Bad Oeynhausen, Germany.

Background: The topic of the effect of the patient table on attenuation in myocardial perfusion imaging (MPI) SPECT is gaining new relevance due to deep learning methods. Existing studies on this effect are old, rare and only consider phantom measurements, not patient studies. This study investigates the effect of the patient table on attenuation based on the difference between reconstructions of phantom scans and polar maps of patient studies.

View Article and Find Full Text PDF

Myocardial microcirculation in athletes and its relationship with cardiac remodeling (CR) and myocardial fibrosis (MF) are not fully understood. We prospectively enrolled 174 athletes and 54 healthy sedentary controls for intravoxel incoherent motion (IVIM) diffusion-weighted imaging of cardiac magnetic resonance imaging. Athletes exhibited significantly lower fast apparent diffusion coefficient (ADC) and perfusion fraction (f) in 16 myocardial segments and each blood supply area compared to controls ( < 0.

View Article and Find Full Text PDF

Background And Aims: Skeletal muscle (SM) fat infiltration, or intermuscular adipose tissue (IMAT), reflects muscle quality and is associated with inflammation, a key determinant in cardiometabolic disease. Coronary flow reserve (CFR), a marker of coronary microvascular dysfunction (CMD), is independently associated with body mass index (BMI), inflammation and risk of heart failure, myocardial infarction, and death. The relationship between SM quality, CMD, and cardiovascular outcomes is not known.

View Article and Find Full Text PDF

This paper proposes the use of artificial intelligence techniques, specifically the nnU-Net convolutional neural network, to improve the identification of left ventricular walls in images of myocardial perfusion scintigraphy, with the objective of improving the diagnosis and treatment of coronary artery disease. The methodology included data collection in a clinical environment, followed by data preparation and analysis using the 3D Slicer Platform for manual segmentation, and subsequently, the application of artificial intelligence models for automated segmentation, focusing on the efficiency of identifying the walls of the left ventricular. A total of 83 clinical routine exams were collected, each exam containing 50 slices, which is 4,150 images.

View Article and Find Full Text PDF

Purpose Of Review: Critical Care Echocardiography (CCE) is now established as an important tool in the intensive care unit (ICU). This paper aims to examine the expanding role of cardiovascular ultrasound in the ICU, focusing on its applications, benefits, and challenges, while highlighting recent advancements shaping the future of critical care echocardiography.

Recent Findings: Non-invasive echocardiographic measurement of hemodynamic parameters including stroke volume, cardiac output, left ventricular filling pressures, and pulmonary pressures have been well-validated against invasive measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!