Microfluidic channels enable the control of cell positioning and the capturing of cells for high-throughput screening and other cellular applications. In this paper, a simple microfluidic platform is proposed for capturing small volumes of cells using sidewall microgrooves. The cell docking patterns in the channels containing sidewall microgroove are also studied. Both numerical and experimental investigations are performed within channels containing sidewall microgrooves of three different widths (i.e., 50, 100 and 200 μm). It is observed that channels containing sidewall microgrooves play an important role in regulating cell positioning and patterning. The obtained results revealed that 10 to 14 cells were positioned inside the sidewall channels of 200 μm width, two to five cells were positioned within the channels of 100 μm width, and one to two individual cells were docked within the sidewall channel of 50 μm width. Particle modelling shows the prediction of cell positioning within sidewall microgrooves. The positions of cells docked within microgroove-containing channels were also quantified. Furthermore, the shear stress variation and cell positioning in the sidewall microgrooves were correlated. Therefore, these sidewall microgroove-containing channels could be potentially useful for regulating cell positioning and patterning on two-dimensional surfaces, three-dimensional microenvironments and high-throughput screening. Cell patterning and positioning are of great importance in many biological applications, such as drug screening and cell-based biosensing.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5997373 | PMC |
http://dx.doi.org/10.5772/60562 | DOI Listing |
Mater Today Bio
June 2024
Institute of Biomedical Engineering, West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu, PR China.
The mechanical environment of vascular endothelial cells (ECs) encompasses a wide range of curvatures due to variations in blood vessel diameters. Integrins, key mediators of cell-matrix interactions, establish connections between the extracellular matrix and the actin cytoskeleton, influencing diverse cellular behaviors. In this study, we explored the impact of spatial confinement on human umbilical vein ECs (HUVECs) cultured within three-dimensional hydrogel microgrooves of varying curvatures and the underlying role of integrins in mediating cellular responses.
View Article and Find Full Text PDFMicromachines (Basel)
March 2024
School of Mechanical Engineering, Jiangsu University of Technology, Changzhou 213001, China.
To improve the capability of nanosecond lasers to process structures with a high aspect ratio, a new method of nanosecond laser processing in closed flowing water was proposed in this paper. The microgrooves on a stainless steel 304 surface were processed by the new method, and the influence of processing parameters on the microgrooves was studied. The comparative experiments of laser processing in still water and overflowing water were also carried out, and the unusual phenomenon of laser processing in different flowing water was discovered by a high-speed camera.
View Article and Find Full Text PDFBiomed Mater
November 2023
School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510640, People's Republic of China.
The cell incubation depends on the cultured surface, but various machining methods produce different surface topographies, but it has not been clear how it is related to the topographic feature until now. Hence, the machined Ti-6Al-4V surface is characterized for preosteoblasts incubation via different mechanical fabrication. The relationship between surface topography created by various machining methods and cell incubation behaviour was explored.
View Article and Find Full Text PDFMicromachines (Basel)
November 2022
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics & Astronautics, 29 Yu Dao Jie Street, Nanjing 210016, China.
Micro multi-grooves are important functional structures widely used in new heat exchanger types, chemical reactors, and other applications. Electrolytic broaching is an efficient and low-cost technology for processing micro multi-grooves. In the conventional electrolytic broaching of multi-grooves, the cathode tools are usually designed as a wedge-shaped tooth structure array with a constant tooth width, and the sidewalls are covered with insulating layers.
View Article and Find Full Text PDFMicromachines (Basel)
June 2021
Institute of Machinery Manufacturing Technology, China Academy of Engineering Physics, Mianyang 621000, China.
In micro-electrical discharge machining (micro-EDM) milling, the cross-section of the microgroove machine is frequently not an ideal rectangle. For instance, there are arc shapes on the bottom and corners, and the sidewall is not steep. The theoretical explanation for this phenomenon is still lacking.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!