Through vial impedance spectroscopy (TVIS) is a product non-invasive process analytical technology which exploits the frequency dependence of the complex impedance spectrum of a composite object (i.e. the freeze-drying vial and its contents) in order to track the progression of the freeze-drying cycle. This work demonstrates the use of a dual electrode system, attached to the external surface of a type I glass tubing vial (nominal capacity 10 mL) in the prediction of (i) the ice interface temperatures at the sublimation front and at the base of the vial, and (ii) the primary drying rate. A value for the heat transfer coefficient (for a chamber pressure of 270 µbar) was then calculated from these parameters and shown to be comparable to that published by Tchessalov (2017).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejpb.2018.05.019 | DOI Listing |
Pharmaceutics
November 2021
DMU Lyo Group, School of Pharmacy, De Montfort University, Leicester LE1 9BH, UK.
Models for ice sublimation from a freeze-drying vial rely on the assumption of a planar ice interface up to ~25% loss of ice mass (which is difficult to qualify) whereas single-vial determinations of the sublimation endpoint (by temperature sensors) are based on the point when the observed temperature reaches a plateau, which cannot differentiate between sublimation and desorption-drying. In this work, the real part capacitance of TVIS vial(s) containing frozen water (during sublimation drying) was measured at 100 kHz. This parameter C'(100 kHz) was shown to be highly sensitive to the shape and volume of the ice mass and is therefore a useful parameter for monitoring ice sublimation.
View Article and Find Full Text PDFSci Rep
July 2020
Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey.
In this work, a novel nanosensing platform was suggested based on ruthenium for the sensitive determination of Idarubicin anticancer drugs. Ruthenium/Vulcan carbon-based nanoparticles were synthesized ultrasonication method and then characterized by transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD). The mean particle size of the nanoparticles calculated by the TEM analysis was found to be 1.
View Article and Find Full Text PDFEur J Pharm Biopharm
July 2020
Leicester School of Pharmacy, De Montfort University, The Gateway, Leicester LE1 9BH, United Kingdom.
Through-vial impedance spectroscopy (TVIS) is a new approach for characterizing product attributes during freeze-drying process development. In this study, a pair of copper foil electrodes was attached to the external surface of a Type I glass tubing vial, of nominal capacity 10 mL and containing 3.5 g of an aqueous solution of 5%w/v lactose, and the impedance spectrum of the vial and contents recorded during a lyophilization cycle.
View Article and Find Full Text PDFInt J Pediatr Otorhinolaryngol
July 2020
Beckman Laser Institute, University of California, Irvine, USA; Department of Biomedical Engineering, University of California, Irvine, USA. Electronic address:
Objectives: To assess the validity of a bench-top model of an optical tympanometry device to diagnose in vitro model of middle ear effusion (MEE).
Methods And Materials: We illuminated an in vitro model of ear canal and tympanic membrane with broadband light and relayed remitted light to a spectrometer system. We then used our proprietary algorithm to extract spectral features that, together with our logistic regression classifiers, led us to calculate a set of simplified indices related to different middle ear states.
PLoS One
February 2020
Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju, Republic of Korea.
This paper reports an outdoor-use polymerase chain reaction (PCR) technology in which stability of resistance temperature detectors (RTDs) is remarkably improved. A thin-film RTD made of non-annealed Pt shows accuracy degradation because the resistance of the RTD tends to decrease during the PCR operation. Thus, the annealing process is applied to the Pt RTD to improve the stability, which is a prerequisite to the accurate measurement of the absolute temperature.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!