Background: Cosmetic dissatisfaction, pain, and chronic discharge may present months till years after enucleation in patients operated because of retinoblastoma. If noninvasive treatment modalities are insufficient, socket reconstruction can be considered. In this study, we discuss the results of dermis-fat exchange to treat these problems.

Method: Four patients with late onset post enucleation socket problems with a request for treatment were included in this prospective study. Socket inspection was documented and pictures at baseline and at a follow-up of at least 6 months were taken. To quantify the problem 'pain', a VAS score at baseline and at follow up was used. For the problem 'cosmetic dissatisfaction' standardized questionnaires were used.

Results: Two patients were included because of cosmetic dissatisfaction; one was included with chronic pain and one with chronic discharge. Reconstruction of the socket using autologous dermis-fat insertion was done in all four. In one of them, severe shrinking of the fat developed. This patient was treated with additional injectable fillers. Both of them, ultimately, had satisfactory results. Autologous fat transplantation also solved the problem of chronic discharge and pain in the two other patients.

Conclusion: Socket reconstruction by autologous dermis-fat exchange may solve different post enucleation socket problems. However, shrinking of the transplanted fat may occur and require additional procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1080/13816810.2018.1488173DOI Listing

Publication Analysis

Top Keywords

socket problems
12
chronic discharge
12
late onset
8
cosmetic dissatisfaction
8
pain chronic
8
socket reconstruction
8
dermis-fat exchange
8
post enucleation
8
enucleation socket
8
autologous dermis-fat
8

Similar Publications

Article Synopsis
  • Patients with transfemoral amputation often face issues related to socket fit and overuse injuries due to uneven joint stress, which can be improved by using bone-anchored prosthetics that connect directly to the bone.
  • This study investigates the relationship between the alignment of the femur and pelvis and how it impacts hip loading asymmetry during walking, both before and one year after receiving a bone-anchored limb implant.
  • The analysis included 19 participants from a larger group who underwent the surgery, comparing their skeletal alignment and hip motion data collected at two different time points to determine the effects of the implantation on their mobility and joint loading.
View Article and Find Full Text PDF

To solve the problems of insufficient stiffness and poor integrity of traditional F-type socket joints, steel screw connections are set along the longitudinal direction between rectangular pipe jacking joints. However, the mechanical properties of F-type socket joints with steel screw connections have not been fully investigated, and the influence of the coefficient of subgrade reaction has not been considered. In this work, through model tests and numerical simulations of F-type socket joints with steel screws under different coefficients of subgrade reaction, the influence of steel screws on the deformation and damage characteristics of F-type socket joints is discussed, and the bending mechanical response of F-type socket joints under different coefficients of subgrade reaction is analyzed.

View Article and Find Full Text PDF

This paper creates 3D models of Kitchon Root Controlled Auxiliary Archwire (Kitchon-RCAA) with different material properties and assembles them onto the main archwire equipped with brackets. By setting different loading methods and conducting Finite Element Analysis (FEA), the range of Orthodontic Torque/Support Force (OT/SF) values can be obtained. From the obtained values, it can be seen that changes in material properties have a significant impact on the mechanical properties of Kitchon-RCAA.

View Article and Find Full Text PDF

Design of semi-open prosthetic socket with constant force for lower limb.

Prosthet Orthot Int

December 2024

School of Intelligent Rehabilitation Engineering, Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.

Background: Prosthetic socket is a key component of the prosthesis for clinical application; its performance directly affects the adaptation of the residual limb to the prosthetic socket. There are long-term and short-term volume fluctuation of the residual limb. The volume fluctuation of the residual limb will lead to the pressure mismatch at the interface of the residual limb and the prosthetic socket, which will cause a series of skin and fit problems.

View Article and Find Full Text PDF

The limb amputations caused due to emergent incidents of trauma injuries and vascular diseases currently represent crucial global problems. The patients/amputees with limb amputation who lost the residual limb (knee-ankle foot system) must depend on the prosthetic limb. Prosthetic clinicians and technicians have attempted to develop optimal limb prosthetics that will enhance the ability and functional elements of the patients/users.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!