Transoral Robotic Surgery: Image Guidance and Augmented Reality.

ORL J Otorhinolaryngol Relat Spec

Department of Otorhinolaryngology and Head and Neck Surgery, Guy's and St. Thomas' NHS Foundation Trust, London, United Kingdom.

Published: October 2019

Transoral robotic surgery (TORS) is being used increasingly as an alternative to conventional open procedures, as its minimally invasive approach results in significant benefits for the patient. This includes faster recovery times and better functional outcomes, less postoperative pain and morbidity associated with open access, shorter operative times, and a reduction in the risk of infection. However, the confined working spaces and sensory deficit, due to a lack of haptic sensation, and proximity to critical vasculature and other vitally important anatomical structures bestow significant challenges on the surgeon. Recent advances in the field of surgical image guidance show promise in helping address these issues. This overview considers a number of important recent developments, all of which exploit imaging technologies that, to a lesser or greater extent, are integrated with the surgical robot platform. In its most advanced form, this combination of technologies results in a fusion of visual information such that the operative field is combined with navigational cues and representations of key anatomical structures through augmented reality registration and overlay. In terms of registration accuracy, image guidance as applied to TORS procedures is an exciting proposition, since the regions of interest (e.g., the tongue base, oropharynx) are typically adjacent to and enclosed by rigid anatomy. Clinical indications and overall effectiveness are discussed together with the limitations of the current technologies. Where appropriate, directions for future work are identified.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000489467DOI Listing

Publication Analysis

Top Keywords

image guidance
12
transoral robotic
8
robotic surgery
8
augmented reality
8
anatomical structures
8
surgery image
4
guidance augmented
4
reality transoral
4
surgery tors
4
tors increasingly
4

Similar Publications

Massive endobronchial hemorrhage leading to Cardiac arrest during EBUS-TBNA: a case of successful resuscitation.

BMC Pulm Med

January 2025

Department of Pulmonary and Critical Care Medicine, School of Medicine, Zhongshan Hospital of Xiamen University, Xiamen University, Xiamen, Fujian, China.

Introduction: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is commonly used for diagnosing mediastinal lymphadenopathy. Despite a low complication rate, severe hemorrhage can occur which is reported in this literature, particularly in hypervascular conditions like Castleman disease.

Methods: A 54-year-old male with idiopathic multicentric Castleman disease underwent EBUS-TBNA for mediastinal lymph node sampling.

View Article and Find Full Text PDF

In order to solve the limitations of flipped classroom in personalized teaching and interactive effect improvement, this paper designs a new model of flipped classroom in colleges and universities based on Virtual Reality (VR) by combining the algorithm of Contrastive Language-Image Pre-Training (CLIP). Through cross-modal data fusion, the model deeply combines students' operation behavior with teaching content, and improves teaching effect through intelligent feedback mechanism. The test data shows that the similarity between video and image modes reaches 0.

View Article and Find Full Text PDF

Mixed reality for preoperative planning and intraoperative assistance of surgical correction of complex congenital heart defects.

J Thorac Cardiovasc Surg

January 2025

Division of Cardiology, The Hospital for Sick Children, Toronto, ON, Canada; Center for Image Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children, Toronto, ON, Canada.

Objectives: Mixed reality (MixR) is an innovative visualization tool that presents virtual elements in a real-world environment, enabling real-time interaction between the user and the combined digital/physical reality. We aimed to explore the feasibility of MixR in enhancing preoperative planning and intraoperative guidance for the correction of various complex congenital heart defects (CHDs).

Methods: Patients underwent cardiac computed tomography or cardiac magnetic resonance and segmentation of digital imaging and communications in medicine (DICOM) images was performed.

View Article and Find Full Text PDF

Pelvic venous disorder (PVD) is a common gynecological disorder caused by chronic pelvic venous congestion. Clinically, it primarily manifests as lower abdominal pain, lower back pain, dyspareunia, increased menstrual flow, and increased vaginal discharge, though positive physical signs are few. The gynecological examination may reveal bilateral ovarian tenderness.

View Article and Find Full Text PDF

: The aim of this study was to compare the outcomes of stiff wire-based 2D3D, 3D3D image fusion (IF), and non-image fusion techniques for simple zone 2 and zone 3 TEVAR cases in terms of radiation exposure, contrast dose, and fusion and projection accuracy. : A single-center retrospective observational study was conducted based on data gathered from patients who underwent TEVAR between 2016 and 2023 at our tertiary aortic referral center. Those who underwent Z2 and Z3 TEVAR during the indicated period were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!