A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes. | LitMetric

AI Article Synopsis

  • Blood glucose levels drop over time in uncentrifuged serum and lithium-heparin tubes, and this decay varies based on blood cell counts and volumes.
  • In a study with 30 healthy volunteers, it was found that glucose decreases more rapidly in lithium-heparin plasma compared to serum, with an average reduction of 7% vs. 5% per hour.
  • The decline in glucose concentration is significantly associated with red and white blood cell counts and specific immune cell types, indicating that these factors impact glucose stability in blood samples.

Article Abstract

Background: Although it is known that glucose concentration exhibits a time-dependent decay in uncentrifuged serum and lithium-heparin blood tubes, no evidence exists on how this variation may depend on blood cell counts (CBC) and volumes.

Methods: Venous blood was drawn from 30 non fasting healthy volunteers into three serum and three lithium-heparin tubes. One serum and lithium-heparin tubes were centrifuged within 15 min after collection and glucose was measured with a hexokinase assay. The second and third serum and lithium-heparin tubes were maintained at room temperature for 1 and 2 h after the first tubes were centrifuged. These other tubes were then centrifuged and glucose was measured. CBC was performed in the first lithium-heparin tube, before centrifugation.

Results: The mean decrease of glucose was higher in lithium-heparin plasma than in serum (0.33 vs. 0.24 mmol/L/h; p<0.001). Glucose concentration decreased by 7% and 5% per hour in lithium-heparin plasma and serum, respectively. In univariate analysis, the absolute decrease of glucose concentration was associated with sex (higher in men than in women), red blood cell (RBC) count, hematocrit, white blood cell (WBC) count, neutrophils and monocytes in both lithium-heparin plasma and serum. In multivariate analysis, the decrease of glucose concentration remained independently associated with RBC, WBC, neutrophils and monocytes in both sample matrices. No significant association was found with platelet number and erythrocyte or platelet volume.

Conclusions: Glucose concentration decrease in uncentrifuged lithium-heparin and serum tubes depends on the baseline number of RBC, WBC, neutrophils and monocytes within the tubes.

Download full-text PDF

Source
http://dx.doi.org/10.1515/cclm-2018-0523DOI Listing

Publication Analysis

Top Keywords

serum lithium-heparin
16
lithium-heparin tubes
12
tubes centrifuged
12
blood cell
8
cell counts
8
glucose concentration
8
uncentrifuged serum
8
lithium-heparin blood
8
blood tubes
8
glucose measured
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!