A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical characteristics associated with pacing-induced cardiac dysfunction: a high incidence of undiagnosed cardiac sarcoidosis before permanent pacemaker implantation. | LitMetric

AI Article Synopsis

  • Previous studies indicated that right ventricular pacing can lead to pacing-induced cardiac dysfunction (PICD), prompting this investigation into clinical characteristics and the occurrence of undiagnosed cardiac sarcoidosis (CS) in patients with atrioventricular block (AVB) showing PICD.
  • Researchers analyzed patients with permanent pacemakers who underwent generator replacement from 2011 to 2017; they were divided into two groups based on their left ventricular ejection fraction post-PPM installation.
  • Findings revealed a higher incidence of cardiac sarcoidosis in the PICD group (46.7% diagnosed post-PPM) despite none having been recognized prior to pacemaker placement.

Article Abstract

Previous studies suggested that right ventricular pacing was associated with pacing-induced cardiac dysfunction (PICD). The purpose of this study was to investigate the clinical characteristics including the incidence of undiagnosed cardiac sarcoidosis (CS) in patients with atrioventricular block (AVB) who manifest PICD. We retrospectively investigated consecutive patients with permanent pacemaker (PPM) undergoing a first-generator replacement surgery with a new PPM or an upgrade procedure to a cardiac resynchronization therapy (CRT) device between December 1, 2011 and June 30, 2017. Patients with AVB showing normal echocardiographic findings before PPM implantation were included and divided into 2 groups: patients with post-PPM left ventricular ejection fraction (LVEF) < 40% and/or undergoing an upgrade procedure to CRT (PICD group) and patients with post-PPM LVEF ≥ 40% who underwent replacement surgery with a new PPM (no-PICD group). There were 15 and 41 patients in the PICD and no-PICD groups, respectively. A wider-paced QRS duration just after the PPM implantation and/or lower pre-PPM LVEF was observed in the PICD group. Furthermore, 46.7% of the PICD patients (7/15) satisfied the diagnostic criteria for CS according to the guideline of the Japanese Circulation Society, although no patients fulfilled these criteria before PPM implantation. In conclusion, a high incidence of CS was observed in patients with AVB who had PICD. However, none of these patients was diagnosed with CS before PPM implantation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-018-1206-5DOI Listing

Publication Analysis

Top Keywords

clinical characteristics
8
associated pacing-induced
8
pacing-induced cardiac
8
cardiac dysfunction
8
incidence undiagnosed
8
undiagnosed cardiac
8
cardiac sarcoidosis
8
permanent pacemaker
8
cardiac
5
characteristics associated
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!