Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Previous studies suggested that right ventricular pacing was associated with pacing-induced cardiac dysfunction (PICD). The purpose of this study was to investigate the clinical characteristics including the incidence of undiagnosed cardiac sarcoidosis (CS) in patients with atrioventricular block (AVB) who manifest PICD. We retrospectively investigated consecutive patients with permanent pacemaker (PPM) undergoing a first-generator replacement surgery with a new PPM or an upgrade procedure to a cardiac resynchronization therapy (CRT) device between December 1, 2011 and June 30, 2017. Patients with AVB showing normal echocardiographic findings before PPM implantation were included and divided into 2 groups: patients with post-PPM left ventricular ejection fraction (LVEF) < 40% and/or undergoing an upgrade procedure to CRT (PICD group) and patients with post-PPM LVEF ≥ 40% who underwent replacement surgery with a new PPM (no-PICD group). There were 15 and 41 patients in the PICD and no-PICD groups, respectively. A wider-paced QRS duration just after the PPM implantation and/or lower pre-PPM LVEF was observed in the PICD group. Furthermore, 46.7% of the PICD patients (7/15) satisfied the diagnostic criteria for CS according to the guideline of the Japanese Circulation Society, although no patients fulfilled these criteria before PPM implantation. In conclusion, a high incidence of CS was observed in patients with AVB who had PICD. However, none of these patients was diagnosed with CS before PPM implantation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00380-018-1206-5 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!