Transplantation of mesenchymal stromal cells (MSCs) is a promising new therapy for heart failure. However, the current cell delivery routes result in poor donor cell engraftment. We therefore explored the role of fibrin glue (FG)-aided, instant epicardial placement to enhance the efficacy of MSC-based therapy in a rat ischemic cardiomyopathy model. We identified a feasible and reproducible method to instantly produce a FG-MSC complex directly on the heart surface. This complex exhibited prompt, firm adhesion to the heart, markedly improving initial retention of donor MSCs compared to intramyocardial injection. In addition, maintenance of retained MSCs was enhanced using this method, together contributing the increased donor cell presence. Such increased donor cell quantity using the FG-aided technique led to further improved cardiac function in association with augmented histological myocardial repair, which correlated with upregulation of tissue repair-related genes. We identified that the epicardial layer was eliminated shortly after FG-aided epicardial placement of MSCs, facilitating permeation of the donor MSC's secretome into the myocardium enabling myocardial repair. These data indicate that FG-aided, on-site, instant epicardial placement enhances MSC engraftment, promoting the efficacy of MSC-based therapy for heart failure. Further development of this accessible, advanced MSC-therapy is justified.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6013428PMC
http://dx.doi.org/10.1038/s41598-018-27881-5DOI Listing

Publication Analysis

Top Keywords

epicardial placement
16
instant epicardial
12
therapy heart
12
heart failure
12
donor cell
12
placement enhances
8
mesenchymal stromal
8
efficacy msc-based
8
msc-based therapy
8
increased donor
8

Similar Publications

Background: Conduction disturbances are a frequent occurrence after tricuspid valve surgeries, and their management is challenging.

Case Presentation: We present a case of 16-year-old male patient who presented with episodes of presyncope. At the age of 7 years, he underwent tricuspid valve replacement surgery with a biological prosthesis for infective endocarditis sourced from a gluteal abscess.

View Article and Find Full Text PDF

Pneumoperitoneum after placement of the temporary pacing wires: transverse colon injury at the base of a diverticulum.

Indian J Thorac Cardiovasc Surg

January 2025

Faculty of Medicine, Clinic of Cardiac Surgery, Comenius University, National Institute of Cardiovascular Diseases, Pod Krasnou Hôrkou 1, 83101 Bratislava, Slovakia.

We present the successful management of a patient presenting with pneumo-peritoneum early after surgery due to transvere colon injury after placement of the temporary pacing wires. The patient was asymptomatic, underwent computed tomography, the temporary pacing wires were removed and he was managed conservatively.

View Article and Find Full Text PDF

Objective: To describe complications and outcomes in cats undergoing epicardial pacemaker (EP) implantation for artificial cardiac pacing and to investigate improvement in clinical signs and health-related quality of life (HRQoL) following surgery.

Methods: 39 client-owned cats that underwent EP placement. Medical records of 4 UK-based referral hospitals were searched and data reviewed retrospectively between July 2010 and December 2022.

View Article and Find Full Text PDF

Cardiac strangulation from leads of an epicardial pacemaker is a rarely reported life-threatening complication. We report the case of a 72-year-old female with history of supraventricular tachycardia status post sino-atrial node ablation with epicardial pacemaker placement who presented to the outpatient setting with shortness of breath. Heart catheterization was performed which showed elevated right and left heart pressures.

View Article and Find Full Text PDF

Identifying the minimum electrode count for locating potential atrial fibrillation drivers in electrocardiographic imaging using unsupervised electrode placement.

Comput Biol Med

December 2024

Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou, Zhejiang, 310053, China; School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, 100191, China.

Article Synopsis
  • The study aimed to determine the minimum number of electrodes needed to effectively measure body surface potentials for identifying atrial fibrillation (AF) drivers using electrocardiographic imaging (ECGI).
  • A total of 24 participants with AF were analyzed using varying electrode counts from 12 to 128, leading to significant findings about electrode placement and mapping accuracy.
  • For optimal results, at least 64 electrodes are needed for persistent AF, and 48 for paroxysmal AF, with the best placements found on the upper anterior and posterior torso regions.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!