A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of Prosthetic Material and Framework Design on Stress Distribution in Dental Implants and Peripheral Bone: A Three-Dimensional Finite Element Analysis. | LitMetric

BACKGROUND The purpose of this study was to evaluate the effects of prosthetic material and framework design on the stress within dental implants and peripheral bone using finite element analysis (FEA). MATERIAL AND METHODS A mandibular implant-supported fixed dental prosthesis with different prosthetic materials [cobalt-chromium-supported ceramic (C), zirconia-supported ceramic (Z), and zirconia-reinforced polymethyl methacrylate (ZRPMMA)-supported resin (ZP)] and different connector widths (2, 3, and 4 mm) within the framework were used to evaluate stress via FEA under oblique loading conditions. Maximum principal (smax), minimum principal (smin), and von Mises (svM) stress values were obtained. RESULTS Minimum stress values were observed in the model with a 2-mm connector width for C and ZP. The models with 3-mm and 4-mm connector widths showed higher stress values than the model with a 2-mm connector width for C (48-50%) and ZP (50-52%). Similar stress values were observed in the 3- and 4-mm models. There was no significant difference in the amount of stress with Z regardless of connector width. The Z and ZP models showed similar stress values in the 3- and 4-mm models and higher stress values than in the C model. Z, ZP, and C showed the highest stress values for the model with a 2-mm connector width. CONCLUSIONS Changes in the material and width of connectors may influence stress on cortical bone, cancellous bone, and implants. C was associated with the lowest stress values. Higher maximum and minimum principal stress values were seen in cortical bone compared to cancellous bone.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6045918PMC
http://dx.doi.org/10.12659/MSM.908208DOI Listing

Publication Analysis

Top Keywords

stress values
36
connector width
16
stress
14
model 2-mm
12
2-mm connector
12
values model
12
values
9
effects prosthetic
8
prosthetic material
8
material framework
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!