Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The purpose of this study was to describe a single institution's experience with transradial access (TRA) for angiographic interventions, and to compare technical success, complication rate and radiation dose of procedures performed with TRA to those performed with transfemoral access (TFA).
Methods: A retrospective cohort study of patients undergoing peripheral interventions via TRA or TFA from 2015 to 2017 was performed. The cohort comprised 33 patients undergoing 44 procedures via TRA and 37 patients undergoing 44 procedures via TFA. Outcome measures were technical success, access-related complications, fluoroscopy time and radiation exposure. Differences at p < 0.05 were considered to be statistically significant.
Results: Baseline characteristics were similar between patients who had procedures via TRA versus those who had procedures via TFA, including age, sex and body mass index. Technical success was achieved in 41/44 (93.2%) of procedures performed via TRA, compared to 44/44 (100%) of procedures performed via TFA (p = 0.241). There were three access-related complications (6.8%) when TRA was performed, compared to none when TFA was performed (p = 0.241). Fluoroscopy time was longer in procedures performed with TRA compared to those performed with TFA (27.3 vs 20.4, p = 0.033). Dose area product (DAP) did not differ with access site choice (p = 0.186).
Conclusions: TRA is a safe and feasible alternative to TFA for a range of peripheral interventions. However, TRA must be performed with prudence as it is not without complications and is technically challenging, leading to longer fluoroscopy time.
Key Points: • Transradial access (TRA) is feasible in a variety of peripheral interventions, achieving success in 93.2% of cases. • Access-related complications are comparable between transfemoral access (TFA) and TRA (p = 0.241), but prudence must be taken during TRA as it could be technically challenging. • Procedures performed with TRA tend to have longer fluoroscopy time compared to those performed with TFA (p = 0.033), but the DAPs are comparable (p = 0.186).