A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Remote results of eversion carotid endarterectomy depending on the suture material used]. | LitMetric

Background: It is known that namely long-term presence of suture material as the only foreign body in autologous conditions may lead to restenosis in the remote period. Such hypothesis was put forward based on good results of reconstructive cardiovascular operations in case of using absorbable suture material.

Objective: Our study was aimed at comparative analysis of remote results of using absorbable suture material polydioxanone and non-absorbable suture material polypropylene in eversion carotid endarterectomy.

Patients And Methods: Over the period from 2002 to 2007, at the Department of Vascular Surgery of the Institute of Surgery named after A.V. Vishnevsky performed a total of 408 carotid reconstructions according to the eversion technique. The study was based on comparative analysis of the remote results of this procedure in two groups of patients: the first group consisted of 121 patients in whom replantation of the internal carotid artery into the common carotid artery was performed using absorbable suture material polydioxanone with the metric sizes 5-0 and 6-0 and the second group comprising 135 patients in whom similar manipulations were performed using non-absorbable suture material polypropylene with the metric size 6-0. In the course of the study it turned out that the remote results might also be influenced by the metric size of polydioxanone, therefore the first group was further subdivided into subgroups: polydioxanone 5-0 - 79 patients and polydioxanone 6-0 - 42 patients.

Results: At baseline, with statistically significant differences by the gender, incidence of unstable atherosclerotic plaque, diameter of the ipsilateral internal carotid artery ≤4 mm, the groups of patients turned out to be in the remote period statistically significantly comparable by such parameters as frequency of the development of a pseudoaneurysm, restenosis of the internal carotid artery, ipsilateral stroke, restenosis-associated stroke, and by survival. However, when comparing the subgroup of patients wherein polydioxanone 6-0 was used and the second group with the initially statistically significant differences by incidence of unstable atherosclerotic plaque and myocardial infarction, in the remote period there was a statistically significant decrease in the incidence rate of restenosis of the internal carotid artery in the first case.

Conclusions: The obtained findings suggested that the absorbable suture material polydioxanone with the metric size 6-0 might be considered as quite a substantiated alternative to the used in cardiovascular surgery non-absorbable suture material polypropylene. Polydioxanone with the metric size 6-0 made it possible to remove or considerably decrease the incidence rate of the development of restenosis of the internal carotid artery after eversion carotid endarterectomy.

Download full-text PDF

Source

Publication Analysis

Top Keywords

suture material
32
carotid artery
24
internal carotid
20
absorbable suture
16
metric size
16
eversion carotid
12
remote period
12
material polydioxanone
12
non-absorbable suture
12
material polypropylene
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!