Study Design: This was a prospective simulator study with 16 healthy male subjects.

Objective: The aim of this study was to compare the relative efficacy of immobilization systems in limiting involuntary movements of the cervical spine using a dynamic simulation model.

Summary Of Background Data: Relatively few studies have tested the efficacy of immobilization methods for limiting involuntary cervical movement, and only one of these studies used a dynamic simulation system to do so.

Methods: Immobilization configurations tested were cot alone, cot with cervical collar, long spine board (LSB) with cervical collar and head blocks, and vacuum mattress (VM) with cervical collar. A motion platform reproduced shocks and vibrations from ambulance and helicopter field rides, as well as more severe shocks and vibrations that might be encountered on rougher terrain and in inclement weather (designated as an "augmented" ride). Motion capture technology quantitated involuntary cervical rotation, flexion/extension, and lateral bend. The mean and 95% confidence interval of the mean were calculated for the root mean square of angular changes from the starting position and for the maximum range of motion.

Results: All configurations tested decreased cervical rotation and flexion/extension relative to the cot alone. However, the LSB and VM were significantly more effective in decreasing cervical rotation than the cervical collar, and the LSB decreased rotation more than the VM in augmented rides. The LSB and VM, but not the cervical collar, significantly limited cervical lateral bend relative to the cot alone.

Conclusion: Under the study conditions, the LSB and the VM were more effective in limiting cervical movement than the cervical collar. Under some conditions, the LSB decreased repetitive and acute movements more than the VM. Further studies using simulation and other approaches will be essential for determining the safest, most effective configuration should providers choose to immobilize patients with suspected spinal injuries.

Level Of Evidence: 3.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0000000000002749DOI Listing

Publication Analysis

Top Keywords

cervical collar
24
cervical
14
cervical rotation
12
cervical spine
8
efficacy immobilization
8
limiting involuntary
8
dynamic simulation
8
involuntary cervical
8
cervical movement
8
configurations tested
8

Similar Publications

Torticollis in a child with Grisel syndrome: A case report and review of the literature.

Int J Surg Case Rep

January 2025

Department of Orthopedics and Trauma Surgery, Tribhuwan University, Institute of Medicine, Kathmandu, Nepal.

Introduction And Importance: Grisel syndrome (GS) is a rare but potentially lethal condition characterized by non-traumatic atlantoaxial subluxation primarily affecting pediatric population following inflammatory condition of head and neck. Early diagnosis and prompt treatment is crucial for better management of symptoms and better outcomes.

Case Presentation: 7-years-old child present with torticollis, sudden onset progressive neck pain, restricted range of motion and bilateral lymphadenopathy after upper respiratory tract infection (URTI).

View Article and Find Full Text PDF

Background: Road traffic injuries (RTIs) are currently the ninth most common cause of mortality and are expected to increase in the future. RTIs rank in the top three reasons why young people die. Because of the high incidence and mortality risk, proper trauma care has been prioritized for RTI patients who present to the emergency department.

View Article and Find Full Text PDF

Available data on radiologists' missed cervical spine fractures are based primarily on studies using human reviewers to identify errors on re-evaluation; such studies do not capture the full extent of missed fractures. To use machine-learning (ML) models to identify cervical spine fractures on CT missed by interpreting radiologists, characterize the nature of these fractures, and assess their clinical significance. This retrospective study included all cervical spine CT examinations performed in adult patients in the emergency department between January 1, 2018 and December 31, 2022.

View Article and Find Full Text PDF

Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).

Setting And Design: In vitro (in silico study) finite element analysis (FEA).

Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.

View Article and Find Full Text PDF

Background: Predictors of difficult fiberscopic intubation have not been fully elucidated. This study focused on identifying radiographic predictors of difficult fiberscopic intubation during general anesthesia in patients with a cervical collar.

Methods: This retrospective study included unconscious patients who underwent orotracheal intubation using a flexible fiberscope while wearing a cervical collar to simulate a difficult airway.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!