Comparison of three non-invasive hemodynamic monitoring methods in critically ill children.

PLoS One

Department of Pediatrics, Division of Pediatric Critical Care, Department of Pediatric, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.

Published: December 2018

Introduction: Hemodynamic parameters measurements were widely conducted using pulmonary artery catheter (PAC) with thermodilution as a reference standard. Due to its technical difficulties in children, transthoracic echocardiography (TTE) has been widely employed instead. Nonetheless, TTE requires expertise and is time-consuming. Noninvasive cardiac output monitoring such as ultrasonic cardiac output monitor (USCOM) and electrical velocimetry (EV) can be performed rapidly with less expertise requirement. Presently, there are inconsistent evidences, variable precision, and reproducibility of EV, USCOM and TTE measurements. Our objective was to compare USCOM, EV and TTE in hemodynamic measurements in critically ill children.

Materials And Methods: This was a single center, prospective observational study in critically ill children. Children with congenital heart diseases and unstable hemodynamics were excluded. Simultaneous measurements of hemodynamic parameters were conducted using USCOM, EV, and TTE. Inter-rater reliability was determined. Bland-Altman plots were used to analyse agreement of assessed parameters.

Results: Analysis was performed in 121 patients with mean age of 4.9 years old and 56.2% of male population. Interrater reliability showed acceptable agreement in all measured parameters (stroke volume (SV), cardiac output (CO), velocity time integral (VTI), inotropy (INO), flow time corrected (FTC), aortic valve diameter (AV), systemic vascular resistance (SVR), and stroke volume variation (SVV); (Cronbach's alpha 0.76-0.98). Percentages of error in all parameters were acceptable by Bland-Altman analysis (9.2-28.8%) except SVR (30.8%) and SVV (257.1%).

Conclusion: Three noninvasive methods might be used interchangeably in pediatric critical care settings with stable hemodynamics. Interpretation of SVV and SVR measurements must be done with prudence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6005547PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0199203PLOS

Publication Analysis

Top Keywords

critically ill
12
cardiac output
12
uscom tte
12
ill children
8
hemodynamic parameters
8
stroke volume
8
measurements
5
tte
5
comparison three
4
three non-invasive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!