A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel gel liner system with embedded electrodes for use with upper limb myoelectric prostheses. | LitMetric

We present the development and evaluation of a gel liner system for upper limb prosthesis users that enables acquisition of electromyographic (myoelectric) control signals through embedded electrodes and flexible, conductive fabric leads. This liner system is constructed using a manufacturing approach rather than by modifying a commercially available liner. To evaluate the efficacy, eight male individuals with transhumeral amputations used this system, with standard myoelectric prostheses, for home trials lasting an average of 7.3 weeks. Before and after the home trials, electrical resistance of the cumulative 218 embedded electrodes and leads within 10 gel liner systems was measured and found to increase slightly (from an average of 13.4 to 27.5 Ω) after usage. While this increase was statistically significant (p = 0.001), all but one of the final resistance values remained low enough to enable consistent myoelectric control. User impressions were evaluated through a questionnaire comparing the liner prototypes to their own myoelectric prosthesis socket interface. Subjects preferred the liner prototype (p = 0.008) over their own system in the clinical areas of comfort, suspension, function, and, especially, ease of use. These results suggest that this gel liner system is a clinically viable option and that it may offer advantages over current clinical technology for users of upper limb myoelectric prostheses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6005573PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0198934PLOS

Publication Analysis

Top Keywords

gel liner
16
liner system
16
embedded electrodes
12
upper limb
12
myoelectric prostheses
12
liner
8
limb myoelectric
8
myoelectric control
8
system
6
myoelectric
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!