A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Use of a modified bubble continuous positive airway pressure (bCPAP) device for children in respiratory distress in low- and middle-income countries: a safety study. | LitMetric

While bubble continuous positive airway pressure (bCPAP) is commonly used in low- and middle-income countries (LMIC) to support neonates with respiratory distress, there are limited non-invasive support options for non-neonatal children. : To demonstrate safety of a new device designed to support children during respiratory distress in LMIC. A paediatric bCPAP device was designed called SEAL-bCPAP (Simplified Ear-plug Adapted-bCPAP). SEAL-bCPAP is constructed from inexpensive, easily obtainable materials. The nasal prong interface was modified from previously described neonatal bCPAP set-ups using commercial ear-plug material to improve nasal seal. A prospective interventional study was conducted to evaluate safety in children with respiratory distress treated with SEAL-bCPAP. Patients aged 30 days to 5 years presenting to a hospital in northern Uganda from July 2015 to June 2016 were screened. Those with moderate-severe respiratory distress and/or hypoxia despite nasal cannula oxygen were eligible for study. Enrolled patients were supported with SEAL-bCPAP until respiratory improvement or death. Complications attributable to SEAL-bCPAP were recorded. Clinical outcomes were compared with historical control pre-trial data. : Eighty-three of 87 enrolled patients were included in the final analysis. No patients had significant SEAL-bCPAP complications. Five patients had mild complications which resolved (four with nasal irritation and one with abdominal distention). Trial patients had significant ( < 0.0001) improvement in their TAL score, respiratory rate and Osat after 2 h of SEAL-bCPAP. Fifty-two of 64 patients (62.7%) with severe illness at Time1 did not have severe illness at Time2 (after 2 h of SEAL-bCPAP) ( < 0.0001). Unadjusted mortality rates were 12.2% (6/49) and 9.6% (8/83), respectively, for pre-trial (historical control) and trial patients ( = 0.64); the study was not powered to show efficacy. : The SEAL-bCPAP device is safe for treatment of respiratory distress in non-neonatal children in LMIC. There is a trend toward decreased mortality that should be evaluated with adequately powered clinical trials.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6858283PMC
http://dx.doi.org/10.1080/20469047.2018.1474698DOI Listing

Publication Analysis

Top Keywords

respiratory distress
20
children respiratory
12
bubble continuous
8
continuous positive
8
positive airway
8
airway pressure
8
pressure bcpap
8
bcpap device
8
low- middle-income
8
middle-income countries
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!