Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The aim of this study was to report clinical outcomes in patients treated with paclitaxel-coated balloons (PCB) for in-stent restenosis (ISR) in both bare metal (BMS) and drug-eluting stent (DES).
Methods: Between May 2009 and December 2015, we treated 155 ISR in 140 patients. At recruitment, 35% of patients had diabetes. Among the lesions, 125 were first occurrence (55 within BMS and 70 within DES) and 30 recurrent; 24 ISR were multi-metal layered. Mean reference diameter was 2.79 ± 0.52 mm and mean lesion length 13.2 ± 7.1 mm. PCB use included 32 Dior I, 97 InPact Falcon, 18 Panthera Lux, and 8 Restore DEB.
Results: At a median follow-up of 442 days, we observed 18 target lesion revascularizations (TLR), one myocardial infarction, 3 cardiac deaths, and 5 non-cardiac deaths. TLR occurrence differed according to type of ISR (4% within BMS, 14% within DES, 28% within recurrent ISR; p<0.05). TLR was associated with PCB type (35% Dior I, 9% InPact Falcon, 0% Panthera Lux and Restore DEB; p<0.05). Multivariable analysis revealed that first-generation PCB without a carrier (hazard ratio [HR] 2.50, 95% confidence interval [CI] 0.96-6.50; p=0.06) and recurrent ISR (HR 7.76, 95% CI 1.56-38.66; p=0.01) correlated with subsequent TLR.
Conclusions: Our results confirm the safety and efficacy of PCB for ISR treatment both within BMS and DES. PCB type and recurrent ISR correlate with subsequent TLR.