Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To compare sensitivity, specificity, accuracy and diagnostic confidence in the differentiation between benign and metastatic bone lesions on whole body planar bone scintigraphy and Evolution SPECT/CT.
Material And Method: Eighty diagnosed or suspected cancer patients with indeterminate lesions on planar scintigraphy were recruited in the present prospective study. Additional whole body Evolution SPECT/CT was performed after whole body planar scintigraphy. All lesions on both imagings were categorized into 5 categories; definitely metastasis, probably metastasis, indeterminate, probably benign and definitely benign. The diagnosis of each lesion was confirmed by follow-up imaging, pathological findings or clinical follow-up for at least 6 months.
Results: Detected lesions on planar scintigraphy and Evolution SPECT/CT imaging were 442 and 477 lesions, respectively.The sensitivity, specificity and accuracy of planar scintigraphy and Evolution SPECT/CT imaging in the diagnosis of metastatic lesions were 27% (95% CI: 13.8, 44.1), 63.2% (95% CI: 58.5, 67.7), 60%, and 97.3% (95% CI: 85.8, 99.9), 100% (95% CI: 96.4, 100) and 99.8%, respectively. Indeterminate lesions on planar scintigraphy were 34.2% (151 lesions from total 442 lesions, which 135 of these 151 indeterminate lesions or 89.4% were located in axial skeleton). Evolution SPECT/CT images were able to characterize all indeterminate lesions.
Conclusion: Differentiation of benign and metastatic lesions by Evolution SPECT/CT images has superior diagnostic performance and diagnostic confidence over the planar scintigraphy. Thus, Evolution SPECT/CT images should be considered in characterization of indeterminate lesions on planar scintigraphy, especially in the axial skeleton.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!