A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hemodynamic Effects of Noninvasive Positive-Pressure Ventilation Assessed Using Transthoracic Echocardiography. | LitMetric

Aims: The aim of this study is to measure the effect of positive-pressure ventilation on heart chamber dimensions, left ventricular (LV) systolic function, LV diastolic function, right ventricular (RV) systolic function, and RV pressure using transthoracic echocardiography.

Settings And Design: This is a prospective study in a single secondary health-care center.

Materials And Methods: A total of 107 patients with obstructive sleep apnea on continuous positive airway pressure (CPAP) therapy were recruited as participants between April and September 2016. Transthoracic echocardiography was performed twice on each participant, before and 15 min after, they used their own CPAP machines, and the echocardiography parameters of both scans were compared.

Statistical Analysis Used: The parametric paired -test was used to compare heart chamber dimensions, left heart diastolic function, left heart systolic function, right heart systolic function, and right heart pressure effect, without and with CPAP. These data were further examined among several subgroups defined by CPAP when the cutoff point was set at 8 cmHO and 10 cmHO. The level of significance was set at 0.05. Statistical analyses were performed using IBM SPSS version 22 (IBM, Armonk, NY, USA).

Results: There were statistically significant reductions, after the application of CPAP, in the heart dimensions, and LV and RV systolic function. There were no significant changes in diastolic function. Concerning right heart pressure, with CPAP, there was a significant increase in the inferior vena cava (IVC) diameter and there was also a significant decrease in IVC variability from 44.56% ± 14.86% to 36.12% ± 11.42%. The maximum velocity of tricuspid regurgitation (TR) decreased significantly from 180.66 ± 6.95 cm/s to 142.30 ± 52.73 cm/s. Such changes were observed in both low and high CPAP subgroups.

Conclusions: When placed on positive pressure, the clinically significant change in IVC diameter and variability and change in trans-TR velocity mean that it would be inaccurate to predict right heart chamber pressure through echocardiogram. Alternative methods for predicting right heart pressure are recommended.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5989542PMC
http://dx.doi.org/10.4103/jcecho.jcecho_53_17DOI Listing

Publication Analysis

Top Keywords

systolic function
20
heart chamber
12
diastolic function
12
pressure cpap
12
heart pressure
12
heart
10
positive-pressure ventilation
8
transthoracic echocardiography
8
chamber dimensions
8
dimensions left
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!