Many care workers at elderly care facilities in Japan suffer occupational low back pain (LBP) despite the utilization of welfare equipment. When introducing welfare equipment such as hoists and sliding boards, education on appropriate care methods using welfare equipment is usually conducted, but the effect of education diminishes with time. This intervention study aimed to examine the effect of re-education on appropriate care methods using welfare equipment on the prevention of care workers' LBP at an elderly care facility. At the intervention facility, 49 care workers were enrolled in ergonomic education program for 1.5 yr in order to improve care methods using welfare equipment. At the non-intervention facility, 33 care workers were not enrolled in the program. Rates of severe LBP were not significantly different between the facilities. However, during the study period, the rate of severe LBP among care workers did not increase at the intervention facility, while it doubled among care workers at the non-intervention facility. The care workers at the intervention facility showed improvement in care methods using welfare equipment during the study period. Hence, we think that re-education regarding appropriate care methods using welfare equipment has the potential to prevent exacerbation of LBP.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6172185PMC
http://dx.doi.org/10.2486/indhealth.2017-0175DOI Listing

Publication Analysis

Top Keywords

welfare equipment
32
care workers
28
care methods
24
methods welfare
24
care
16
appropriate care
16
intervention facility
12
facility care
12
welfare
8
equipment
8

Similar Publications

Background/objectives: Malnutrition and sarcopenia are interrelated health concerns among the elderly. Each condition is associated with increased mortality, morbidity, rehospitalization rates, longer hospital stays, higher healthcare costs, and reduced quality of life. Their combination leads to the development of "Malnutrition-Sarcopenia Syndrome" (MSS), characterized by reductions in body weight, muscle mass, strength, and physical function.

View Article and Find Full Text PDF

Clinical Efficacy of Three-Dimensional-Printed Pure Titanium Fracture Plates with Locking Screw Systems in Distal Tibia Fractures.

Medicina (Kaunas)

January 2025

Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.

Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.

View Article and Find Full Text PDF

: Measuring joint range of motion (ROM) is essential for diagnosing and treating musculoskeletal diseases. However, most clinical measurements are conducted using conventional devices, and their reliability may significantly depend on the tester. This study implemented an RGB-D (red/green/blue-depth) sensor-based artificial intelligence (AI) device to measure joint ROM and compared its reliability with that of a universal goniometer (UG).

View Article and Find Full Text PDF

Extending an existing animal facility is a challenging process that requires consideration of both engineering and biological aspects. In this sense, integration with ongoing activities must not alter the animals' microbiological condition or welfare, as they usually remain in the facility while these activities occur. The objective of this work was to describe and evaluate the practical biosafety considerations during the enlargement of a specific pathogen-free (SPF) rodent facility.

View Article and Find Full Text PDF

Background/objectives: Interventional radiology (IR) utilizing X-rays can lead to occupational radiation exposure, posing health risks for medical personnel in the field. We previously conducted a survey on the occupational radiation exposure of IR nurses in three designated emergency hospitals in Japan. Our findings indicated that a hospital with 214 beds showed a higher lens-equivalent dose than hospitals with 678 and 1182 beds because the distance between the X-ray irradiation field and the IR nurse's position of the hospital with 214 beds was shorter than those of 678 and 1182 beds.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!