A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Flow Diversion via LVIS Blue Stent within Enterprise Stent in Patients with Vertebral Artery Dissecting Aneurysm. | LitMetric

Flow Diversion via LVIS Blue Stent within Enterprise Stent in Patients with Vertebral Artery Dissecting Aneurysm.

World Neurosurg

Department of Neurosurgery, Stroke Center, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea; Severance Institute for Vascular and Metabolic Research, Yonsei University College of Medicine, Seoul, Republic of Korea. Electronic address:

Published: September 2018

A new Low-profile Visualized Intraluminal Support device (LVIS Blue) is a braided stent that provides a higher degree of metal coverage. This stent may be beneficial for complete obliteration of an aneurysm due to not only its support of a higher occlusion rate using coils inside of the aneurysm but also its flow-diverting effect. We introduce and describe a new flow-diversion technique using an LVIS Blue stent within an Enterprise stent for patients with vertebral artery (VA) dissecting aneurysms. A 6-Fr guiding catheter was positioned in the ipsilateral VA. A microcatheter with an inner diameter of 0.021 inches was navigated and positioned across the dissecting segment of the VA. An Enterprise stent was then deployed and used to cover the dissecting segment by pushing the pusher wire of the stent while simultaneously unsheathing the microcatheter. The microcatheter was navigated along the remaining pusher wire to the distal VA through the Enterprise stent. An LVIS Blue stent was introduced and positioned such that it overlapped the previous stent in order to divert blood flow away from the dissecting segment. We present a case in which this technique was used to successfully obliterate a dissecting aneurysm while maintaining the VA patency with vessel wall remodeling. The LVIS Blue stent-within-an-Enterprise stent technique may be an effective treatment option for patients with VA dissecting aneurysms as an alternative technique to flow diverters.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2018.06.029DOI Listing

Publication Analysis

Top Keywords

lvis blue
20
enterprise stent
16
stent
12
blue stent
12
dissecting segment
12
stent enterprise
8
stent patients
8
patients vertebral
8
vertebral artery
8
artery dissecting
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!