A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A real-time loop-mediated isothermal amplification method for rapid detection of Lawsonia intracellularis in porcine fecal samples. | LitMetric

Porcine proliferative enteritis is a common diarrheal disease characterized by thickening of the intestinal mucosa in swine due to enterocyte proliferation, which is caused by Lawsonia intracellularis. In this study, a real-time loop-mediated isothermal amplification (LAMP) assay was developed to detect L. intracellularis based on the conserved region of the 16S ribosomal RNA gene. The optimal reaction conditions of the real-time LAMP was 65 °C for 60 min. The LAMP products could be detected by both real-time turbidity and direct visual inspection. The assay was specific for L. intracellularis, as no cross-reaction was observed with other pathogens. The detection limit of the real-time LAMP assay was 1.4 × 10pg of L. intracellularis DNA, which was the same as that of real-time PCR and approximately 100 times more sensitive than that of conventional PCR. Of the 136 clinical samples, L. intracellularis DNA was identified in 60 samples by real-time LAMP, which was the same as real-time PCR and higher than conventional PCR (36.8%, 50/136). The specific, sensitive and rapid real-time LAMP assay developed in this study could be a useful alternative tool in point-of-care (POC) diagnosis of L. intracellularis infection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mimet.2018.06.002DOI Listing

Publication Analysis

Top Keywords

real-time lamp
16
lamp assay
12
real-time
9
real-time loop-mediated
8
loop-mediated isothermal
8
isothermal amplification
8
lawsonia intracellularis
8
assay developed
8
intracellularis dna
8
real-time pcr
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!