Background: Sepsis is a severe systemic inflammatory state in response to infection. The induction of heat shock protein 70 (HSP70) by heat stress has been reported to protect against lethal effects of sepsis. In clinical situation, inhalation of thermal water has been used empirically in the treatment of chronic diseases of respiratory tract. Thus, thermal steam aerosolization may have beneficial effects on sepsis via HPS70 induction.

Objective: The present study tested the hypothesis that thermal steam aerosolization could protect against lipopolysaccharideinduced sepsis in rats.

Material And Method: Male Spraque-Dawley rats were subjected to steam aerosolization at 40°C for 1 hour before intraperitoneal injection of 10 mg/kg lipopolysaccharide (LPS). Blood pressure, heart rate and core temperature were recorded in two hours interval. At the end of the study period, vascular response to vasoconstrictor of isolated aortic rings ex vivo was assessed. Serum proinflammatory cytokines, IL-1beta and IL-6, were analyzed using ELISA technique. Plasma nitric oxide was determined using nitrate/nitrite fluorometric assay Kit. HSP70 expression, heat shock factor-1 (HSF-1) mRNA level and nuclear factor-kappa B (NF-kappa B) activity in the lungs of rats were investigated using western blot analysis, real-time quantitative PCR and transcription factor kits for NF-kappa B p65, respectively.

Results: Thermal steam aerosolization treatment prevented the fall in systolic, diastolic, mean arterial blood pressures induced by LPS and restored the vascular response to adrenaline. LPS significantly increased plasma nitrate/nitrite concentration, serum IL-1 beta and IL-6 levels, and NF-kappa B activity in rat lung lysate which were reduced by thermal steam aerosolization. Thermal steam aerosolization induced both HSP70 and HSF-1 mRNA expression.

Conclusion: The present study suggests that thermal steam aerosolization can delay the stage of shock in LPS-induced septic rats. It shows a beneficial therapeutic effect and may be applied to the clinical approach for septic shock patient.

Download full-text PDF

Source

Publication Analysis

Top Keywords

steam aerosolization
32
thermal steam
28
thermal
8
aerosolization
8
heat shock
8
effects sepsis
8
vascular response
8
hsf-1 mrna
8
nf-kappa activity
8
steam
7

Similar Publications

Light curing infection control barriers: do some types jeopardize the concept of conventional bulk-fill composites?

BMC Oral Health

November 2024

Biomaterials Department, Faculty of Dentistry, Ain-Shams University, Organization of African unity, Cairo, Egypt.

Background: Using infection control barriers (ICBs) on light curing units (LCUs) became mandatory to achieve proper infection control measures without jeopardizing the integrity of the restorations, especially at deeper layers. This study explored the effect of two ICBs on the irradiance of the LCU, as well as the degree of conversion (DC) and flexural strength (FS) of two types of bulk-fill composites. Water vapor permeability (WVP) of both barriers was also assessed to evaluate the capability of such barriers to prevent transmission of blood and saliva droplets and aerosols.

View Article and Find Full Text PDF

Responses of precipitation and water vapor budget on the Chinese Loess Plateau to global land cover change forcing.

J Environ Manage

August 2024

Institute of Global Environmental Change, Department of Earth and Environmental Science, School of Human Settlements and Civil Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China.

There have been notable changes in precipitation patterns on the Loess Plateau (LP) of China in recent decades, and numerous attribution studies have focused on sea surface temperature anomalies and atmospheric circulation changes induced by aerosols and greenhouse gases emission. However, the influences of global land use and land cover change (LULCC) as an important forcing factor in the climate system on regional precipitation remains poorly understood. In this study, we quantified the impacts of LULCC on precipitation and the water vapor budget in the LP region, utilizing data from LULCC forcing experiments conducted by the sixth phase of the Coupled Model Intercomparison Project (CMIP6).

View Article and Find Full Text PDF

Pulmonary delivery of icariin-phospholipid complex prolongs lung retention and improves therapeutic efficacy in mice with acute lung injury/ARDS.

Colloids Surf B Biointerfaces

September 2024

Key Laboratory of Bioactive Substances and Resources Utilization of Chinese Herbal Medicine, Institute of Medicinal Plant Development (IMPLAD), Chinese Academy of Medical Sciences & Peking Union Medical College, No. 151 Malianwa North Road, Haidian District, Beijing 100193, PR China. Electronic address:

Icariin has been shown the promising therapeutic potential to treat inflammatory airway diseases, yet its poor lung distribution and retention restrict the clinical applications. To this end, this work aimed to prepare an icariin-phospholipid complex (IPC) formulation for sustained nebulization delivery that enabled excellent inhalability, improved lung exposure and prolonged duration of action. Icariin was found to react with soybean phospholipid to form supramolecular IPC, which was able to self-assemble into nanoparticle suspension.

View Article and Find Full Text PDF

Inhalation exposure to nanosized aerosols of disinfectants for the application of continuous releasing sprayers and fogger.

Int J Environ Health Res

November 2024

Department of Preventive Medicine, Institute for Environmental Research, Yonsei University, Seoul, Republic of Korea.

This study aimed to investigate the airborne exposure to aerosols according to the particle size distribution of three different spray types (, , and ) and compare the concentrations of inhaled aerosols between children and adults. Airborne aerosols released from three products were observed using size-segregated particle measurements, and particle concentrations deposited in the respiratory tracts of adults and children were estimated using multi-path particle dosimetry lung deposition models. All types of sprayers generated the most nanoparticles (~100 nm).

View Article and Find Full Text PDF

With the increasing need for particulate matter (PM) monitoring, the demand for light-scattering sensors that allow for real-time measurements of PM is increasing. This light-scattering method involves irradiating light to the aerosols in the atmosphere to analyze the scattered light and measure mass concentrations. Humidity affects the measurement results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!