Objective: To develop an indirect competitive chemiluminescent enzyme immunoassay( CLEIA) for the detection of bisphenol A in milk samples.
Methods: The CLEIA conditions including antigen coated concentration, concentration of methanol, concentration of enzyme labeled anti-antibody, p H and ionic strength were optimized to build competitive inhibition curve, determine the linear range and detection limit, and study the recovery of spiked milk samples.
Results: In the standard curve of the optimized CLEIA, the half maximal inhibitory concentration( IC_(50)) was 3. 95 ng/m L and the limit of detection( LOD) was 0. 66 ng/m L. The CLEIA showed good recoveries with spiked milk ranging from 95. 0%-112. 9% with the relative standard deviation of0. 93%-3. 96%.
Conclusion: The proposed method has a high sensitivity and good specificity and is suitable for the determination of bisphenol A in milk samples.
Download full-text PDF |
Source |
---|
Sensors (Basel)
January 2025
Department of Obstetrics and Gynecology, Shengjing Hospital of China Medical University, Shenyang 110004, China.
Fluorescent iron nanoclusters are emerging fluorescent nanomaterials. Herein, we synthesized hemoglobin-coated iron nanoclusters (Hb-Fe NCs) with a significant fluorescence emission peak at 615 nm and investigated the inner-filter effect of fluorescence induced by a manganese dioxide nanosheet (MnO NS). The fluorescence quenching of Hb-Fe NCs by a MnO NS can be significantly reversed by the addition of ascorbic acid.
View Article and Find Full Text PDFBMC Gastroenterol
January 2025
Department of General Surgery, Fuwai Central China Cardiovascular Hospital, No. 1, Fuwai Road, Zhengdong New District, Zhengzhou, Henan, 451460, PR China.
Objective: To investigate the effect of capecitabine on the sensitivity of oxaliplatin and on the level of transcription factor forkhead box P1 (FOXP1) and gamma-glutamyl transpeptidase (GGT) in patients with intermediate and advanced gastric cancer.
Methods: A total of 152 Patients with advanced gastric cancer who were continuously diagnosed and treated in our hospital were selected as the study objects. The general data were retrospectively analyzed.
Ann Clin Lab Sci
November 2024
School of Medical Laboratory, Tianjin Medical University, Tianjin, China
Objective: To evaluate the analytical and diagnostic performance of anti-cyclic citrullinated peptide (anti-CCP) antibody measured by the light-initiated chemiluminescence assay (LICA).
Methods: A total of 193 patients with rheumatoid arthritis (RA) and 211 controls were included. Serum anti-CCP levels were assessed by LICA and enzyme-linked immunosorbent assay (ELSIA).
Ther Drug Monit
January 2025
Department of Immunology, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain; and.
Background: Tumor necrosis factor is a crucial proinflammatory cytokine in immune-mediated diseases. Tumor necrosis factor inhibitors (TNFi), such as infliximab and adalimumab, effectively treat rheumatological and digestive disorders. However, challenges such as primary nonresponse, secondary treatment failure, or adverse reactions limit their efficacy.
View Article and Find Full Text PDFVet Sci
January 2025
College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, China.
(PCV2) is the main and primary causative agent of Postweaning Multisystemic Wasting Syndrome (PMWS). To date, immunoperoxidase monolayer assay (IPMA), indirect immunofluorescent assay (IFA), and enzyme linked immunosorbent assay (ELISA) are the most commonly diagnostic methods for detecting PCV2 antigens. However, these methods require specialized equipment and technical expertise and are suitable for laboratory use only.