Objective: To evaluate the concordance of high resolution T2-weighted (HR-T2W) and Gd-T1W for mass detection in internal acoustic canal (IAC) or cochlear in sensorineural hearing loss (SNHL).

Material And Method: The retrospective study of patients with SNHL undergoing magnetic resonance imaging (MRI) IAC protocol was performed. HR-T2W and Gd-T1W were separately reviewed for any mass in IAC or cochlear.

Results: One hundred eight cases were available for evaluation with 43 males and 65 females (mean age of 56.04 years old; range 15 to 86 years old). Symptoms of SNHL on right side were 39 cases (36.1%), left side 39 cases (36.1%), both sides 15 cases (13.9%), and asymmetric SNHL 15 cases (13.9%). Twenty two (20.4%) cases had mass in IAC and/or cochlear demonstrated on both HR-T2W and Gd-T1W. No discrepancy of abnormality detection between both pulse sequences was found.

Conclusion: HR-T2W was as accurate as Gd-T1W in detecting mass in IAC and cochlear in patients with SNHL. Screening with HR-T2W could be used with confidence and might be reasonable to reducing cost of the MRI study in appropriate setting of patients presenting with SNHL.

Download full-text PDF

Source

Publication Analysis

Top Keywords

hr-t2w gd-t1w
12
mass iac
12
high resolution
8
internal acoustic
8
acoustic canal
8
sensorineural hearing
8
hearing loss
8
iac cochlear
8
patients snhl
8
side cases
8