Non-adaptive signal processing methods have been successfully applied to extract fetal electrocardiograms (fECGs) from maternal abdominal electrocardiograms (aECGs); and initial tests to evaluate the efficacy of these methods have been carried out by using synthetic data. Nevertheless, performance evaluation of such methods using real data is a much more challenging task and has neither been fully undertaken nor reported in the literature. Therefore, in this investigation, we aimed to compare the effectiveness of two popular non-adaptive methods (the ICA and PCA) to explore the non-invasive (NI) extraction (separation) of fECGs, also known as NI-fECGs from aECGs. The performance of these well-known methods was enhanced by an adaptive algorithm, compensating amplitude difference and time shift between the estimated components. We used real signals compiled in 12 recordings (real01-real12). Five of the recordings were from the publicly available database (PhysioNet-Abdominal and Direct Fetal Electrocardiogram Database), which included data recorded by multiple abdominal electrodes. Seven more recordings were acquired by measurements performed at the Institute of Medical Technology and Equipment, Zabrze, Poland. Therefore, in total we used 60 min of data (i.e., around 88,000 R waves) for our experiments. This dataset covers different gestational ages, fetal positions, fetal positions, maternal body mass indices (BMI), etc. Such a unique heterogeneous dataset of sufficient length combining continuous Fetal Scalp Electrode (FSE) acquired and abdominal ECG recordings allows for robust testing of the applied ICA and PCA methods. The performance of these signal separation methods was then comprehensively evaluated by comparing the fetal Heart Rate (fHR) values determined from the extracted fECGs with those calculated from the fECG signals recorded directly by means of a reference FSE. Additionally, we tested the possibility of non-invasive ST analysis (NI-STAN) by determining the T/QRS ratio. Our results demonstrated that even though these advanced signal processing methods are suitable for the non-invasive estimation and monitoring of the fHR information from maternal aECG signals, their utility for further morphological analysis of the extracted fECG signals remains questionable and warrants further work.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5988877PMC
http://dx.doi.org/10.3389/fphys.2018.00648DOI Listing

Publication Analysis

Top Keywords

ica pca
12
fetal
8
signal processing
8
methods
8
processing methods
8
fetal positions
8
fecg signals
8
signals
5
comparative effectiveness
4
effectiveness ica
4

Similar Publications

Purpose: To describe a case in which a right replaced posterior cerebral artery (PCA) was associated with an ipsilateral superior cerebellar artery (SCA) type persistent trigeminal artery (PTA) variant.

Methods: A 53-year-old man who had been diagnosed with chronic dissection of the left vertebral artery (VA) 4 months previously underwent follow-up magnetic resonance (MR) angiography using a 3-Tesla scanner.

Results: MR angiography showed a slightly dilated left VA at the terminal segment without interval change.

View Article and Find Full Text PDF

The cerebral arterial circle morphologic variability has been extensively studied. The posterior cerebral artery (PCA) variants are rarely identified, except from the first segment (P1) hypoplasia or absence. Due to its unique morphology, the computed tomography angiography (CTA) of a 34-year-old female patient was further investigated.

View Article and Find Full Text PDF

Correlation between P2-PCA volume flow rate and BOLD cerebrovascular reactivity in patients with symptomatic carotid artery occlusion.

AJNR Am J Neuroradiol

December 2024

From the Department of Neurosurgery (AW., J.F., L.M.H., J.P., M.G., V.S., C.H.B.v.N., L.R., G.E., M.S.), Clinical Neuroscience Center (AW., J.F., L.M.H., J.P., T.S., M.G., V.S., C.H.B.v.N., S.W., A.R.L., Z.K., L.R., G.E., M.S.), Department of Neuroradiology (Z.K.) and Department of Neurology (S.W., A.R.L.), University Hospital Zurich, Zurich, Switzerland; University of Zurich (AW., J.F., L.M.H., J.P., T.S., M.G., V.S., C.H.B.v.N., S.W., A.R.L., Z.K., L.R., G.E., M.S.), Zurich, Switzerland; cereneo Center for Neurology and Rehabilitation (A.R.L.), Vitznau, Switzerland.

Background And Purpose: Identifying and assessing hemodynamic and flow status in patients with symptomatic internal carotid artery (ICA) occlusion is crucial for evaluating recurrent stroke risk. The aim of this study was to analyze the correlation between two quantitative imaging modalities: (1) blood oxygenation level-dependent (BOLD) cerebrovascular reactivity (CVR) and (2) quantitative magnetic resonance angiography (qMRA) with non-invasive optimal vessel analysis (NOVA), measuring volume flow rate (VFR). Comparing these modalities is relevant for assessing collateral circulation and hemodynamic impairment.

View Article and Find Full Text PDF

Variants of the cerebral arterial circle, both common and rare, are frequently documented. The authors present a distinct case involving a 54-year-old male patient who underwent a computed tomography angiogram (CTA), which was analyzed using planar slices and 3-dimensional reconstruction. In this case, the left posterior cerebral artery (PCA) received the posterior communicating artery (PComA) 7 mm distal to its origin from the basilar artery (BA).

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on identifying road hypnosis by analyzing both external and internal characteristics of drivers, specifically eye movement and EEG data.
  • Data from vehicle and virtual driving experiments are preprocessed and trained using advanced machine learning techniques like self-attention models and deep belief networks.
  • The proposed identification method demonstrates effective recognition of road hypnosis and enhances understanding of its characteristics and mechanisms, providing insights for improving driving safety.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!