The aim of the present study was to evaluate the cyclic fatigue of two anatomic finishing files: XP-Endo Finisher and XP-Clean. Roughness pattern and the micro-hardness of the files were also assessed. Instruments were subjected to cyclic fatigue resistance measuring the time to fracture in an artificial stainless-steel canal with a 60° angle and a 5-mm radius of curvature. The fracture surface of all fragments was examined with a scanning electron microscope. The roughness of the working parts was quantified by using a profilometer and the micro-hardness test was carried out using a Vickers hardness tester. Results were statistically analyzed using a student´s t-test at a significance level of P < 0.05. Weibull analysis was also performed. XP-Endo Finisher presented significantly longer cyclic fatigue life than XP-Clean instruments (P<0.05). XP-Endo Finisher was able to withstand 1000% more cycles to fracture when compared to XP-Clean instruments. SEM visual inspection of the fracture surfaces revealed fractographic characteristics of ductile fracture in all tested instruments; wide-ranging forms of dimples were identified and no plastic deformation in the helical shaft of the fractured instruments was observed. When mean life was compared XP-Endo Finisher lasted longer than XP-Clean with a probability of 99.9%. XP-Endo Finisher instruments also exhibited significantly lower roughness than XP-Clean instruments (P<0.05). No differences in the micro-hardness was observed between the files (P>0.05). It can be concluded that XP-Endo Finisher instruments showed improved performance when compared with XP-Clean instruments, demonstrating higher cyclic fatigue resistance and lower roughness.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/0103-6440201801903 | DOI Listing |
Int J Dent
December 2024
College of Dentistry, King Saud University, P. O. Box 68004, Riyadh 11527, Saudi Arabia.
XP-endo files are composed of Max-Wire alloy, which was developed by FKG Dentaire (La Chaux-de-Fonds, Switzerland). This alloy, known as Martensite-Austenite Electropolish Flex, is the first NiTi alloy used in endodontics to combine the shape memory effect with superelasticity for use in clinical practice. This article aims to provide a comprehensive overview of the existing knowledge and evidence regarding different XP-endo files and systems, XP-endo Finisher (XPEF), XP-endo Shaper (XPES), XP-endo Retreatment (XPER), XP-endo Rise (XPE-Rise), and XPE-Rise Retreatment (XPE-Rise-R), to help clinicians understand their different properties and recommended clinical uses.
View Article and Find Full Text PDFJ Endod
November 2024
Postgraduate Program in Dentistry, Iguaçu University (UNIG), Nova Iguaçu, Rio de Janeiro, Brazil; Postgraduate Program in Dentistry, University of Grande Rio (UNIGRANRIO), Rio de Janeiro, Rio de Janeiro, Brazil.
Introduction: The intracanal antibacterial effectiveness of a bioceramic medication was compared with calcium hydroxide pastes in different vehicles.
Methods: Extracted mandibular incisors with a single long oval canal were selected and distributed into 5 groups based on anatomically paired microcomputed tomographic analyses. The root canals were prepared up to an instrument size 35/04 and contaminated for 30 days with a mixed bacterial culture from subgingival biofilm added with Enterococcus faecalis.
Bioengineering (Basel)
October 2024
Department of Human Genetics, School of Dental Medicine, University of Belgrade, 11000 Beograd, Serbia.
Eradication of microorganisms present in the root canal system during endodontic therapy is one of the critical factors affecting the final outcome of endodontic treatment. However, even adequate technique of the root canal treatment and use of irrigants according to the established protocol does not lead to the complete elimination of microorganisms during endodontic treatment. The presence of (.
View Article and Find Full Text PDFJ Dent
January 2025
Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, University of British Columbia, Vancouver, Canada. Electronic address:
Objective: This study evaluated the efficacy of the ProTaper Universal Retreatment system (PTUR) and XP-endo Finisher R instrument (XPFR) in removing 64-month-old root filling material from minimally-instrumented mandibular molar canals.
Methods: Forty-eight root canals with Vertucci type II or IV configurations from 30 mandibular molars were instrumented to size 20/0.04 taper using Vortex Blue NiTi rotary instruments and irrigated with the GentleWave system.
J Dent
December 2024
Department of Dentistry, Endodontics Division, Health Sciences Center, Federal University of Santa Catarina, Florianopolis, Santa Catarina, Brazil. Electronic address:
Objective: To evaluate the efficacy of supplementary methods, including Passive Ultrasonic Irrigation (PUI), ultrasonic inserts, XP-Endo Finisher, XP-Endo Finisher R, Easy Clean, sonic activation, and the Er:YAG laser (SWEEPS), in removing residual filling material (RFM) during endodontic retreatment.
Method: Five electronic databases and gray literature were searched on May 5, 2024. Two independent reviewers selected laboratory studies that assessed the efficacy of supplementary methods for RFM removal using micro-CT imaging.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!